C&S Electronics Computemp 5 Owner's Manual

Multiple use digital thermometer with 7 day memory

Advertisement

Owner's Manual
Computemp 5
Multiple use Digital Thermometer
With 7 Day Memory
Congratulations. You are now the owner of one of the most
remarkable and fascinating ways available to observe temperature
changes. It is our sincere hope that you will find the Computemp a
fun and fascinating instrument.
The magic of micro-electronic
technology makes your Computemp entertaining and useful.
Computemp can monitor up to nine
Locations from one central unit with the
Optional rotary switch accessory.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Computemp 5 and is the answer not in the manual?

Questions and answers

Richard
May 18, 2025

How can I get one repaired

1 comments:
Mr. Anderson
May 23, 2025

To get a C&S Electronics part number 5 (Computemp 5) repaired, you should avoid adjusting the back trimmer, as it is for factory use only. If the unit is damaged, such as from improper adjustment or other causes not covered under warranty (e.g., tampering, misuse, or accidental damage), it may need to be returned for repair. Allow up to four weeks for return delivery of your unit.

This answer is automatically generated

Summary of Contents for C&S Electronics Computemp 5

  • Page 1 Owner’s Manual Computemp 5 Multiple use Digital Thermometer With 7 Day Memory Congratulations. You are now the owner of one of the most remarkable and fascinating ways available to observe temperature changes. It is our sincere hope that you will find the Computemp a fun and fascinating instrument.
  • Page 2: Specifications

    SPECIFICATIONS LINE POWER: (103-133V), 60Hz (200-240VAC 50/60 Hz opt.) ADAPTER OUTPUT: 700MA, 9 VAC POWER RATINGS: 7.35 VA (7.35W) BATTERY LIFE: 36 hours backup operation RANGE: -40° to + 175°F (-40°C to 80°C) ACCURACY: + 1% over range REPEATABILITY: 1.5°F (1°C) TEMP.
  • Page 3 FEATURES MAIN TEMPERATURE 30 feet (9M) sensor is primarily intended for measuring ambient outdoor temperature, but other uses are limited only by imagination (other lengths available). AUX TEMPERATURE Measures any temperature within 6 feet (1.8M) of the unit (other lengths available). TIME Current time of day is displayed.
  • Page 4 OPERATING INSTRUCITONS If you have not already done so, plug in the Computemp, this is accompanied by a chirp. The unit is in the RUN MODE and is alternately displaying MAIN temperature, AUX temperature and TIME. The three small lights changing with the digital read-out indicate what is being displayed.
  • Page 5: Battery Installation

    SILENCING ALARMS The TIME alarm may be reset (shut off) for 24 hours by pressing SELECT. The TEMP alarm may likewise be reset by pressing SELECT. TEMP alarm will not be reactivated until the measured temperature leaves and returns back to the alarm temperature setting. The alarms will not sound when the lights are off.
  • Page 6 UNIT CALIBRATION If the unit is not recording the proper temperature, use the following procedures. If the temperature is off by more than 10 degrees of actual there is some other problem with your unit. (Do not attempt to re-calibrate). The temperature adjustment trimmers are positioned behind the two front hole covers (Main &...
  • Page 7 PROBE INSTALLATION Run the main sensor through a window or any other convenient topening. The ideal location for he sensor is under the eave on the north side of the building. If this is not possible, avoid locations that abnormally warm for any reason or where the sun can shine directly on the sensor.
  • Page 8: Limited One Year Warranty

    LIMITED ONE YEAR WARRANTY C&S Electronics, Inc. warrants this product to be free from defects in workmanship and material under normal use and conditions for a period of one year from the date of original purchase. Should service be required by reason of any defect or malfunction during the warranty period, C&S Electronics, Inc.

Table of Contents