  • Page 3 Welcome Thank you for purchasing our IP camera! This user’s manual is designed to be a reference tool for your system. Please read the following safeguard and warnings carefully before you use this series product! Please keep this user’s manual well for future reference!
  • Page 4: Important Safeguards And Warnings

    Important Safeguards and Warnings 1.Electrical safety All installation and operation here should conform to your local electrical safety codes. The power shall conform to the requirement in the SELV (Safety Extra Low Voltage) and the Limited power source is rated 12V DC or 24V AC in the IEC60950-1. We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation.
  • Page 5 Always use the dry soft cloth to clean the device. If there is too much dust, please use the water to dilute the mild detergent first and then use it to clean the device. Finally use the dry cloth to clean the device.
  • Page 6: Table Of Contents

    Table of Contents General Introduction ........................1 Overview ........................1 Features ......................... 1 Specifications ........................ 2 1.3.1 Performance ......................2 1.3.2 Factory Default Setup ................... 3 Structure ............................ 11 Multiple-function Combination Cable ..............11 Framework and Dimension ..................12 Bidirectional talk......................13 2.3.1 Device Connection ....................
  • Page 7 FAQ ............................27 Appendix Toxic or Hazardous Materials or Elements ............... 28...
  • Page 8: General Introduction

    1 General Introduction 1.1 Overview This series IP camera integrates the traditional camera and network video technology. It adopts audio and video data collection, transmission together. It can connect to the network directly without any auxiliary device. This series IPC uses standard H.264 video compression technology and G.711a audio compression technology, which maximally guarantee the audio and video quality.
  • Page 9: Specifications

    Support electronic shutter and gain setup.  Support video watermark function to avoid vicious video modification. 1.3 Specifications 1.3.1 Performance Please refer to the following sheet for IPC performance specification. Model HDD3MIA Series Parameter Main TI Davinci high performance DSP Processor Embedded LINUX System...
  • Page 10: Factory Default Setup

    Working 10%~90% Humidify Dimensions(m ¢160x118.5 Weight 1.25g Installation Support various installation modes(Enclosure and bracket is optional) 1.3.2 Factory Default Setup Please refer to the following sheet for factory default setup information. Default setup Function Item Setup Type HDD3MIA Brightness Contrast...
  • Page 11 Default setup Function Item Setup Type HDD3MIA Saturation Gain mode Auto Gain limit Exposure mode Auto Auto iris Enable Scene mode Auto Day/night mode Auto Flip Disable Bit stream General type Encode H.264B mode 1080P 720P(1280*72 Resolution (1920*1080) PAL: 25 Frame rate (FPS)...
  • Page 12 Default setup Function Item Setup Type HDD3MIA Snap type General snap 1080P 720P(1280*7 Image size (1920*1080) Snapshot Quality Better Interval Privacy mask Enable Overlay Channel title Enable Time title Enable Snapshot C:\PictureDownload Path path Record path C:\RecordDownload Enable Enable Main stream Encode G.711A...
  • Page 13 Default setup Function Item Setup Type HDD3MIA User name Password Disable ,CN99 DDNS Server type Server IP none Port Domain none DDNS name User name none Password Update period IP filter Trusted sites Disable SMTP server none Port Anonymity Disable...
  • Page 14 Default setup Function Item Setup Type HDD3MIA Enable Disable Server IP 0.0.0.0 Auto register Port 7000 Sub-device none WIFI On(Enable) Enable Real-time monitor Command Enable Disable Anti-dither 5 seconds Sensitivity Record Enable Channel Record 10 seconds Delay Relay (Alarm) Enable...
  • Page 15 Default setup Function Item Setup Type HDD3MIA Record Enable channel Record delay Relay (Alarm) Enable output Relay (Alarm) delay Send email Disable Disable Activation Address Snapshot Disable Relay (Alarm) output Enable Disable Relay (Alarm) Enable output Relay output delay Send email...
  • Page 16 Default setup Function Item Setup Type HDD3MIA delay Enable Disable Record Enable Record delay Relay (Alarm) Enable output Relay output delay FTP enable Disable Server IP Port User name anonymity Password Remote share storage path Emergency Destination(Storag storage Disable local path...
  • Page 17 Default setup Function Item Setup Type HDD3MIA 00:00:00 of the first Sunday of the Start time month 00:00:00 of the second Monday of End time the month Synchronize Disable with NTP NTP server clock.isc.org Port Update period Protocol PELCOD Address...
  • Page 18: Structure

    2 Structure 2.1 Multiple-function Combination Cable You can refer to the following figure for multiple-function combination cable information. See Figure Figure 2-1 Please refer to the following sheet for detailed information. Port Name Function Connection Note Video output Output analog video signal. It can connect to the VIDEO OUT port TV monitor to view the video.
  • Page 19: Framework And Dimension

    Port Name Cable Name Note Color Alarm input port 2. It is to receive the on-off signal Grey ALARM_IN2 from the external alarm source. Alarm output port. It is to output the alarm signal to the alarm device. White ALARM_NO NO: normal open alarm output port.
  • Page 20: Bidirectional Talk

    Figure 2-3 2.3 Bidirectional talk 2.3.1 Device Connection Before the operation, connect the active pickup to the audio input port of the device. Connect the active speaker to the audio output port of the device. Please make sure the client-end device has the audio input and output function.
  • Page 21 Figure 2-4...
  • Page 22: Installation

    3 Installation This series IPC can be put on the table to realize surveillance. Or you can use the bracket or the in- ceiling installation to realize the hang function. Please refer to the steps listed below. 3.1 Device Installation Step 1 Use the inner hexagonal wrench (provided) to loose the three inner hexagon screws in the dome cover and then open the cover.
  • Page 23 Step 3 Draw out the cable exit and four screw holes in the installation position according to the device pedestal. Dig the four plastic expansion bolt holes and cable exit. Insert the four plastic expansion bolts into the screw holes Step 4 Adjust the camera pedestal to the proper position and then draw the cable through the cable exit you just dug in the ceiling (wall).
  • Page 24  e): Put the enclose back after you completed the setup. With IR light Without IR light Figure 3-4 Please note, the screws in the following figure are the optical adjustment component. Please make sure it is outward and do not allow it to touch the X-Y-Z axis module. See Figure 3-5 Figure 3-5 Step 7 Put the dome cover back and then put the three inner hexagon screws into the holes of the device.
  • Page 25: Sd Card Installation

    3.2 SD Card Installation Important Before you install the SD card, please unplug he power cable to shut down the device! First, please refer to the step1 in the chapter 3.1 to open the device. Second, please adjust the proper position to install the SD card. Last, please refer to the step 7 in the chapter 3.1 to complete the installation.
  • Page 26 With IR light Without IR light Figure 3-8...
  • Page 27: Quick Configuration

    4 Quick Configuration 4.1 Overview Quick configuration can search current IP address, modify IP address. Please note the search only applies to the IP addresses in the same segment. 4.2 Operation Run the Hybrid NDVR, click the “Menu” button on the bottom right corner, select “Add/Del IP camera”, and click “IPC search”, you’ll see an interface shown in Figure 4-1.
  • Page 28 Figure 4-2 Select one IP address and then click “Add to DVR”, then “Exit”, you can see an interface shown in Figure4-3. Figure 4-3...
  • Page 29 After camera added, right click on it and select the “IP camera setup” item; you can go to the configuration interface. If you want to modify the device IP address without logging in the device web interface, you can go to the software interface to set.
  • Page 30 Figure 4-5 Please note to login with HTTP port (Default 80) in web client and Data port (Default 37777) in software. Otherwise, you cannot login the device. For detailed information and operation instruction of the quick configuration tool, please refer to the IP_System_Quick_Start_Guide.
  • Page 31: Web Operation

    5 Web Operation This series IPC product support the Web access and management via PC. Web includes several modules includes monitor channel preview, PTZ control, system configuration, alarm and etc. IP camera factory default setup:  IP address: 192.168.1.108.  User name: admin ...
  • Page 32 Figure 5-2 If it is your first time to login in, system pops up warning information to ask you whether install control webrec.cab or not after you logged in for one minute. Please click OK button, system can automatically install the control. When system is upgrading, it can overwrite the previous Web too. If you can’t download the ActiveX file, please check whether you have installed the plug-in to disable the control download.
  • Page 33 Figure 5-4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction.
  • Page 34 6 FAQ I cannot boot up Please click RESET button for at least five seconds to restore the device. factory default setup. card write Do not set the SD card as the storage media to storage the times schedule record file. It may damage the SD card duration. I cannot use the When disk information is shown as hibernation or capacity is 0, disk as the storage...
  • Page 35: Appendix Toxic Or Hazardous Materials Or Elements

    Appendix Toxic or Hazardous Materials or Elements Toxic or Hazardous Materials or Elements Component Name Cr VI PBDE Circuit Board ○ ○ ○ ○ ○ ○ Component Device ○ ○ ○ ○ ○ ○ Construction Material ○ ○ ○ ○ ○...

Table of Contents