GREISINGER GTMU - MP Operating Manual

Transmitter for temperature

Advertisement

Quick Links

T20.0.4X.6C-03
Operating Manual
from version V3.2
Transmitter for
Content
1
INTENDED USE
2
GENERAL ADVICE
3
SAFETY INSTRUCTIONS
4
DISPOSAL NOTES
5
ASSIGNMENT OF ELBOW-TYPE PLUG (DEPENDING ON TYPE)
6
GENERAL INSTALLATION INSTRUCTIONS:
7
DESIGN TYPES, DIMENSION
8
DISPLAY FUNCTIONS
8.1
M
EASURING DISPLAY
8.2
M
/M
V
IN
AX
ALUE
9
ERROR AND SYSTEM MESSAGES
10 CONFIGURATION OF THE DEVICE
11 NOTES TO THE CALIBRATION SERVICES
12 SPECIFICATION
GREISINGER
D - 93128 Regenstauf, Hans-Sachs-Straße 26
+49 (0) 9402 / 9383-0
GTMU - MP
M
EMORY
electronic GmbH
+49 (0) 9402 / 9383-33
temperature
WEEE-Reg.-Nr.: DE93889386
info@greisinger.de
2
2
2
2
3
3
3
4
4
4
4
5
6
6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GTMU - MP and is the answer not in the manual?

Questions and answers

Summary of Contents for GREISINGER GTMU - MP

  • Page 1 T20.0.4X.6C-03 Transmitter for temperature GTMU - MP Operating Manual from version V3.2 Content INTENDED USE GENERAL ADVICE SAFETY INSTRUCTIONS DISPOSAL NOTES ASSIGNMENT OF ELBOW-TYPE PLUG (DEPENDING ON TYPE) GENERAL INSTALLATION INSTRUCTIONS: DESIGN TYPES, DIMENSION DISPLAY FUNCTIONS EASURING DISPLAY ALUE EMORY...
  • Page 2 T20.0.4X.6C-03 Operating Manual GTMU - MP page 2 of 6 _____________________________________________________ _____________________________________________________________________________ 1 Intended use The device measures the temperature of air or non corrosive / non ionizing gases. The safety instructions (see chapter 3) have to be observed. The device must not be used for purposes and under conditions for that the device had not been designed.
  • Page 3 T20.0.4X.6C-03 Operating Manual GTMU - MP page 3 of 6 _____________________________________________________ _____________________________________________________________________________ 5 Assignment of elbow-type plug (depending on type) 4-20mA (2-wire connection) voltage (3-wire connection) voltage (4-wire connection) = supply voltage +Uv = signal + = signal + = GND / signal...
  • Page 4 T20.0.4X.6C-03 Operating Manual GTMU - MP page 4 of 6 _____________________________________________________ _____________________________________________________________________________ 8 Display Functions 8.1 Measuring display During normal operation the temperature in [°C] or [°F] is displayed. °C 8.2 Min/Max Value Memory watch Min values (Lo): press ▼ shortly once display changes between „Lo„...
  • Page 5 T20.0.4X.6C-03 Operating Manual GTMU - MP page 5 of 6 _____________________________________________________ _____________________________________________________________________________ 10 Configuration of the device ATTENTION! Follow these instructions to configure the functions of the device: UNIT Press SET until the first parameter appears in the display If a parameter should be changed, press ▼ or ▲, The device changed to the setting –...
  • Page 6 T20.0.4X.6C-03 Operating Manual GTMU - MP page 6 of 6 _____________________________________________________ _____________________________________________________________________________ 11 Notes to the calibration services Calibration certificates - DKD-certificates - other certificates: If device should be certificated for its accuracy, it is the best solution to return it with the referring sensors to the manufacturer.

Table of Contents