General Information; Troubleshooting - Sony CMD-Z1 Service Manual

Aep model/ uk model portable digital cellular telephone with accessories
Table of Contents

Advertisement

General information

No GSM test mode is implemented in the Z1 for use with the ROM Loader Software. For the software or the
Language Set update simply connect the Z1 with the Level Shifter and run the ROM Loader Software
(CMD− Z1.EXE). The Z1 does not have to be switched on!
The switch settings of the Level Shifter are as follows:
Switch
Main power
Vpp
IGN/Vpp
FROMRP
GSM power

Troubleshooting

Cause 1
– The error message "ERROR : SIO Receive timeout" appears after starting the program and trying to
set up the connection between PC and Z1.
Remedy 1
– Check the connection between MT (mobile terminal), Level Shifter, and PC. Also make sure that the
Level Shifter's power is switched on (both switches). Both the Main Power LED and the GSM Power
LED must light up.
– Check whether COM1 or COM2 is active.
Intel ROM
always on
off
always on
disabled (factory set to off position)
always on
Sharp ROM
always on
on
always on
disabled (factory set to off position)
always on
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents