Fix the DSC label

A DSC warning label is supplied with US versions of this radio.
To comply with FCC regulations, this warning label must be affixed in a location that is
Make sure that the chosen location is clean and dry before applying this label.

Connect the Radio Cables

The connectors are on the rear of the base unit, as follows:
GPS/COM connector. For connection to GPS device via NMEA (If you are not using
this, be sure to put the protective cap securely over the connector to protect it from
moisture and dust).
GPS/COM cable. For above connector. See the following table for wiring and color
codes.
Red Power wire. Connect this to the Positive (+) battery terminal. Check that a 7 Amp
fuse is installed on this power cable close to the battery.
Black Power wire. Connect this to the Negative (-) battery terminal.
External Speaker connector. Connect to an external speaker BEFORE powering on
the radio. Use a 4 Ohm 6 Watt external speaker. White wire to speaker (+). Bare wire to
speaker (-). NOTE: Ensure wires are electrically insulated if not used.
ANT. A radio antenna is not supplied. A suitable radio antenna must be mounted
and connected before operating this radio. Consult your dealer for advice if necessary.
GND. A ground connection is not usually required.
NMEA 2000 connector. For connection to a compatible NMEA 2000 network.
clearly visible from the operating controls of this radio.
Simrad - RS12 Operation and Installation Instructions
CAUTION