9-3. Instruction of troubleshooting
Start
Indoor unit
operates.
Outdoor unit
doesn't
operate.
Outdoor unit
Outdoor unit
doesn't
operates only
operate
in Test Run
operation. w
even in
Test Run
operation. w
Check room
Refer to
temperature
"How to check
inverter/
thermistor.
Refer to 9-7.
compressor".
"Test point
diagram and
voltage".
POWER lamp
All lamps
Flash on and off
Flash on and off
at 0.5-second
at 0.5-second
intervals
intervals
Cause:
Cause:
Indoor unit
Indoor/
• The horizontal
Outdoor unit
vane is not
• Mis-wiring
installed
or trouble
correctly.
of serial signal
Refer to 9-6.
Refer to 9-6.
E "Check of
D "How to
installation of
check of
the horizontal
mis-wiring
vane".
and serial
signal error.
Indoor unit operates.
Outdoor unit doesn't
operate normally.
Indoor unit
Unit doesn't
operates, when
operate
EMERGENCY
normal
OPERATION
operation in
switch is pressed.
COOL or
HEAT mode.
Refer to
Refer to 9-6.B
"Check of
"Check of
R.V. coil".
remote controller
and receiver
P.C. board".
POWER lamp
POWER lamp
2-time flash
3-time flash
Cause:
Cause:
Indoor unit
Indoor unit
• Trouble of
• Trouble of
room temp-
indoor fan
erature/
motor
indoor coil
thermistor
Refer to 9-6.
Check room
A "Check of
temperature
indoor fan
thermistor
motor".
and indoor
coil thermis-
tor.
Refer to 9-7.
"Test point
diagram and
voltage".
w"Test Run operation"
means the operation
within 30 minutes after
EMERGENCY OPERATION
switch is pressed.
Indoor unit
doesn't receive
the signal from
remote controller.
Indoor unit
doesn't operate,
when
EMERGENCY
OPERATION
switch is pressed.
1. Check indoor / outdoor
connecting wire.
(Check if the power
is supplied to the
indoor unit.)
2. Refer to 9-6.C
"Check of indoor
electronic control
P.C. board and indoor
fan motor".
Left lamp
POWER lamp
of AREA lamp
5-time flash
4-time flash
Cause:
Cause:
Outdoor unit
Indoor unit
• Outdoor
• Trouble of
power
indoor unit
system
control
abnormality
system
Refer to
Replace the
indoor
"How to check
inverter/
electronic
compressor".
control
P.C. board.
17
If blinking of OPERATION
INDICATOR lamp cannot
be checked, it can be checked
with failure mode recall function.
OPERATION
INDICATOR
lamp on the
indoor unit is
flashing on
and off.
PLASMA/WASH lamp
2-time flash
cause:
Indoor unit
• Trouble of PLASMA
DEODORIZNG power
control and/or PLASMA
AIR PURIFYING power
control
Refer to 9-6.F"Check of
PLASMA DEODORIZING
power" or 9-6.G"Check of
PLASMA AIR PURIFYING
power".
Refer to outdoor unit service manual.
POWER lamp
POWER lamp
7-time flash
6-time flash
Cause:
Cause:
Outdoor unit
Outdoor unit
• Trouble of
• Trouble of
outdoor
thermistor
control
in outdoor
system
unit
Refer to
Replace the
"Check of
inverter P.C.
outdoor
board or
thermistors".
the outdoor
electronic
control P.C.
board.
POWER lamp
14-time flash
Cause:
Outdoor unit
• Other
abnormality
Check
"Flow chart of
the detailed
outdoor unit
failure mode
recall function."