Note: For proper operation of optional accessories, the wires from the switch to the control
valve must be connected exactly as shown:
CSG3924PRA
• 10,000/40,000 Btu/hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water): Maximum 14" W.C., Minimum* 11" W.C.
• Certified Standards: Z21.11.2-2007, Z21.60-1996, CGA2.26-M96
CSG3924NRA
• 10,000/40,000 Btu/hr
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3" W.C.
• Inlet Gas Pressure (in. of water): Maximum 10.5" W.C., Minimum* 5" W.C.
• Certified Standards: Z21.11.2-2007, Z21.60-1996, CGA2.26-M96
* For purpose of input adjustment
123639-01D
WIRING DIAGRAM
O.D.S. PILOT
IGNITOR
THERMOCOUPLE
THERMOCOUPLE
CONNECTION
SWITCH
Wire Harness
REMOTE-READY MODELS ONLY
SPECIFICATIONS
www.desatech.com
THERMOPILE
PILOT
VALVE
PILOT
OUT
TPTH
TP
TH
Thermopile
PIEZO
29