4. Push the "filter sign reset" button on the
remote controller.
The display "
Cleaning the air outlet and exterior
CAUTION
• Do not use gasoline, benzene, thinner, polish-
ing powder or liquid insecticide.
• Do not use hot water of 50°C or higher, as doing
so may result in discoloration or deformation.
(1) Clean with dry soft cloth.
(When it is difficult to remove stains, use water
or neutral detergent.)
If the following phenomenon occurs, con-
tact your dealer.
WARNING
• When the air conditioner is malfunctioning
(giving off a burning odour, etc.) turn off
power to the unit and contact your local
dealer.
Continued operation under such circumstances
may result in a failure, electric shocks or fire
hazards.
• Contact your dealer.
Phenomenon
• If a safety device such as a fuse, a breaker or
an earth leakage breaker frequently actuates;
Take the following actions before contact.
Do not turn on the main power switch.
• If the ON/OFF switch does not properly work;
Take the following actions before contact.
Turn off the main power switch.
Phenomenon
• Water leaks out from the air conditioner.
Take the following actions before contact.
Stop the operation.
English
" vanishes.
Phenomenon
• The "OPERATION lamp", "INSPECTION dis-
play" or "UNIT No." is winking and lit, and "MAL-
FUNCTION CODE" is displayed.
UNIT No.
INSPECTION
display
Take the following actions before contact.
Inform the dealer of the details being displayed
on the remote controller.

Product type and running noise

Model No.
15
Model
Function
Combina-
tion system
Condenser
cooling
method
Air blowing
Type
method
Rated cool-
ing capacity
1700 2200 2800 3600 4500 5600 7100
(W)
Rated heat-
ing capacity
1900 2500 3200 4000 5000 6300 8000
(W)
Operating sound
dB (A) (conversion
32
33
values under
noise-less room)
Explanation
• The actual value during operation is higher than
the indicated value under the influence of envi-
ronmental noise and echo.
• The above data is subject to change by means
of technological innovation.
• The operating sound is based on the rear side
suction inlet, and the external static pressure
10Pa.
Operating sound for under suction inlet:
[operating sound for rear side suction inlet] +
5dB.
However, when installation to which the exter-
nal static pressure becomes low is carried out
5dB or more may go up.
OPERATION lamp
C
L
H
INDOOR UNIT No. in
which a malfunction occurs
MALFUNCTION CODE
20
25
32
40
50
Heat pump type
Separate type
Air cooling type
Direct air-blowing type
33
33
34
35
63
36
4