Airpax Dimensions ADI-24/2400N Owner's Manual

Unintertuptable power supply (external battery type)

Advertisement

Quick Links

Airpax Dimensions, Inc.
4467 White Bear Parkway
St. Paul, MN 55110-7626
OWNER'S MANUAL
Airpax Dimensions, Inc.
Unintertuptable Power Supply
Form 121585
(651) 653-7000
Fax (651) 653-7600
(External Battery Type)
OWNERS MANUAL for Models:
ADI-24/2400N UPS
ADI-24/4800N UPS
Including Option "D"
U.P.S.
121585B
FEBRUARY 2007

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADI-24/2400N and is the answer not in the manual?

Questions and answers

Summary of Contents for Airpax Dimensions ADI-24/2400N

  • Page 1 121585B Airpax Dimensions, Inc. 4467 White Bear Parkway (651) 653-7000 St. Paul, MN 55110-7626 Fax (651) 653-7600 OWNER'S MANUAL FEBRUARY 2007 Airpax Dimensions, Inc. U.P.S. Unintertuptable Power Supply (External Battery Type) OWNERS MANUAL for Models: ADI-24/2400N UPS ADI-24/4800N UPS Including Option "D"...
  • Page 2 There is a risk of INVERTERS acid exposure. There is also a risk of high current discharge from shorting the battery that can Model ADI-24/2400N UPS cause fire and explosion. Model ADI-24/4800N UPS CAUTION: Be sure both the U.P.S. and the external AC input circuit breaker or fuse are Including Options "D"...
  • Page 3 3. INSTALLATION charging of the internal input capacitor. 3.01 The following instructions should be thor- 3.05.2 Use stranded copper wire between oughly read and understood before installation. the battery and inverter as indicated. A line fuse 3.02 CAUTION: The U.P.S. produces hazardous must be installed between the battery and the voltages, to avoid risk of harm or fire the unit must inverter.
  • Page 4 termainal of the switch. The input terminal of the 3.09 120 VAC Input (120/240 VAC with "D" switch should be connected to 5 Amp. fused +24 option) VDC. The cable clamp strain relief should be used to 3.09.1 120 VAC (120/240 VAC with "D" secure the field wires.
  • Page 5 4. START UP / OPERATION 4.05 To operate the U.P.S., turn the On/ 4.01The battery charger will operate anytime Off switch to “ON”. Assure that the output breakers that there is external AC power and the battery is are reset. If a remote switch is used, the inverter is not 100% charged.
  • Page 6 The High temperature light indicates the for 5 seconds then reconnecting them. U.P.S. has overheated. The unit will automatically 5.05 Call Airpax Dimensions, Inc. for technical turn back on when it has cooled to 40 C. Verify that assistance and/or a Return Authorization Number the U.P.S.
  • Page 7 FIG. 1 INSTALLATION WIRING WARNING: CONNECTING THE BATTERY WITH THE WRONG POLARITY TO THE U.P.S WILL CAUSE DAMAGE THAT IS NOT COVERED UNDER THE WAR- RANTY. FUSE REMOTE A.C. A.C. Input Battery Output Transfer Charger A.C. INPUT OUTPUT A.C. INPUT EARTH GROUND EARTH GROUND REMOTE TEMPERATURE SENSE...
  • Page 8: Limited Warranty

    Lading and Delivery receipt with damage noted therein must accompany any claims for freight damage. Claims for shortage and lost shipments must be made in writing to Airpax Dimensions, St. Paul, MN within 10 days of date of shipment. Claims not reported within this time frame will not be honored.