Do you have a question about the 3600-MPX and is the answer not in the manual?
Questions and answers
Summary of Contents for Adash 3600-MPX
Page 1
! User configuration of measuring channels via the Adash 3600 Setup program ! User definition up to four different measurements for each channel via the Adash 3600 Setup program ! Capability to connect up to 8 these modules to one Adash 3600 set Ref: 07022003 KM ADASH Ltd., Czech Republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz...
ICP supply and the signal, - ICP negative pole of the supply and the signal, SHLD sensor cable shield. ADASH Ltd., Czech Republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz...
Adash 3600-MPX Description of Adash 3600-MPX The Adash 3600-MPX module serves to connect up to 8 sensors with ICP supply to the Adash 3600-MAIN module. The original one-channel basic set Adash 3600 thus becomes multi-channel and enables cyclic measurement on all the mounted measurement channels, if extended with this module.
Page 5
As soon the valid values measured at the selected channel are displayed on the displays, the decimal point switches off. ADASH Ltd., Czech Republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz...
Extending the Set with the Adash 3600-MPX Module The connection of the Adash 3600-MPX module to the Adash 3600 set is done according to the following schematic: Fig. Schematic of connection of the 3600-MPX module to the Adash 3600 system ADASH Ltd., Czech Republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz...
The Set with a Number of Adash 3600-MPX Modules Fig. Interconnection of MPX output (OUT) terminal connectors ADASH Ltd., Czech Republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz...
Pay attention to the correct polarity of the supply voltage! The positive voltage is always at the first terminal connector on the left. ADASH Ltd., Czech Republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz...
Page 9
A of RS-485 black conductor, signal B of RS-485. 5. Connection of terminal connectors of the output signal from the Adash 3600-MPX module (+OUT, -OUT) to the input terminal connectors of the Adash 3600-MAIN module (+ICP, -ICP) via a shielded conductor.
Page 10
Fig. Interconnection of signal terminal connectors of the 3600-MAIN and 3600-MPX modules 6. Connection of vibration sensors. To connect vibration sensors with ICP supply to the Adash 3600 set, a special shielded twisted cable is supplied, which is marked and connected as follows:...
Page 11
Channel 7 Fig. Connection of channels 7 and 8 7. Replace the terminal connector covers. The extension of the Adash 3600 set with the 3600-MPX module is completed and the system is ready for measurement. NOTICE. Each module of Adash 3600 system has individual unique internal address on RS-485 - see User's guide Vibration Monitoring System Adash 3600 (3600main-com-pwr_man_en.pdf - List of...
- DIN rail Dimensioned Sketch of Adash 3600-MPX 33 mm 106 mm 48 mm 58 mm ADASH Ltd., Czech Republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz...
Need help?
Do you have a question about the 3600-MPX and is the answer not in the manual?
Questions and answers