High Voltage Transformer

The high voltage transformer is located on the
right side of the microwave oven, beneath the
magnetron.
WARNING: Prior to servicing the transformer, be
certain the capacitor is discharged. Manually
discharge it by placing an insulated-handle
screwdriver between the diode connection on the
capacitor and the oven chassis ground.
To remove the high voltage transformer:
1. Remove the outer cover. (See
2. Disconnect wiring to the high voltage
transformer.
Disconnect
View From Right Side
Disconnect
.)
Outer Cover
Disconnect
Disconnect
3. Remove 6 Phillips-head screws from the bottom
cover of the microwave oven cabinet.
4. Remove 4 Phillips-head screws that attach the
high voltage transformer to the bottom plate,
then remove the transformer.