gas appliances. Should any lines ever rupture,
NEVER attempt to splice them. A new line
should always be installed. We recommend
any LP gas line services be performed by
your dealer or an authorized service person.
Always close main valve at LP tank when
servicing any gas appliance. This prevents
any gas leakage which could result in an
explosion or cause serious bodily injury.
I
WARNING
Never check gas lines for leaks with an
open flame. Do not check for leaks using
ammoniated or chlorinated household
type detergents. These detergents can
cause cracks to form on the metal tubing
and brass fittings. Take the unit to a
qualified LP gas service technician to find
and repair the leak. Keep the tank valve
closed and all of the appliances turned
off when the unit is stored. If any of the
LP gas valves do not close leak-tight by
hand, consult a service technician.
Although your LP gas system was thoroughly
inspected for leaks before delivery, gas fittings
can loosen from vibration during travel. Your
LP gas system should be inspected at least
every three months and before every trip. If
leak is suspected, check immediately!
LP Gas Lines
The primary manifold
is located under the
unit. Copper tubing
with flare fittings are
used
as
secondary
lines running to the
Exterior LP Hookup
An
optional
exterior
LP
gas
appliance
quick connect socket
is available on some
units.
Precautions and Recommendations
• Inspect LP fill valve for foreign material
before refueling.
• Shut off tow vehicle and pilot lights when
refueling gas tanks.
• Never check for gas leaks with an open
flame match, etc.
• Visually inspect gas lines for any problem
periodically.
• Have dealer inspect gas system yearly and
before and after long trips. Always have
qualified technician check and make any
repairs in your gas system.
Notice
This gas piping system is designed for
use of liquefied propane gas only. Do not
connect natural gas to this system. Do not
fill container(s) to more than 80 percent of
capacity. Securely cap inlet(s) when not
connected for use. After turning on gas,
except after normal container replacement,
test gas piping and connections to appliances
for leakage with soapy water or bubble
solution. Do not use products that contain
ammonia or chlorine.
I
All pilot lights, appliances and their
igniters (see operating instructions) must
be turned off during refueling of motor
fuel tanks and/or LP gas containers.
Climate Differences
The appliances in your vehicle will not function
if the LP gas does not vaporize. Propane will
continue to vaporize down to -44 degrees F.
Propane has become the main type of LP gas
used in RV's in recent years. Butane should
not be used. The LP gas dealer will have the
correct type or blend for his locale. If you
plan on traveling from a warm climate to a
cold climate, check with your local gas dealer
to see if the blend he supplies is appropriate
for the part of the county you plan on visiting.