Vogelzang International Norseman 1500 Owner's Manual

Vogelzang International Norseman 1500 Owner's Manual

Solid fuel warm air furnace
Hide thumbs Also See for Norseman 1500:

Advertisement

N
S
F
ORSEMAN
Olid
uEl
W
A
F
ARM
iR
uRNAcE
models 1500/2500 Owners manual
(save this manual for future reference)
READ ALL INSTRUCTIONS CAREFULLY
UL 391-06
This furnace meets
BEFORE INSTALLINg OR OPERATINg
U.S. Test Standard:
ThIS FURNACE.
NOTE: INSTALLATION mUST BE
FAILURE TO FOLLOw INSTRUCTIONS
mAY RESULT IN PROPERTY DAmAgE,
COmPLETED BY A qUALIFIED
BODILY INjURY, OR EvEN DEATh.
hEATINg EqUIPmENT INSTALLER!
DO NOT USE ThIS FURNACE IN A
REFER TO mARkINgS ON
FURNACE LABELS FOR
mOBILE hOmE, mANUFACTURED hOmE,
ADDITIONAL INFORmATION.
TENT OR TRAILER – No ExcEptioNs!
Vogelzang International corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
Page 1
VGZ-018 / 051809.0
NORSEMAN™ 1500/2500 FuRNAcE /

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Norseman 1500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vogelzang International Norseman 1500

  • Page 1 ORSEMAN Olid ™ uRNAcE models 1500/2500 Owners manual (save this manual for future reference) READ ALL INSTRUCTIONS CAREFULLY UL 391-06 This furnace meets BEFORE INSTALLINg OR OPERATINg U.S. Test Standard: ThIS FURNACE. NOTE: INSTALLATION mUST BE FAILURE TO FOLLOw INSTRUCTIONS...
  • Page 2: Safety Precautions

    103 HT Listed Residential This should disappear after a short period of time Type and Building Heating Appliance chimney. continued on next page use a 6” diameter chimney or larger, that is high Page 2 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.0...
  • Page 3 National Fire Protection Association (NFPA) publication, Using Coal and Wood Stoves Safely, NFPA No. HS-10- 1978. The address of the NFPA is Batterymarch Park, Quincy, MA 02269. Page 3 VGZ-018 / 051809.0 NORSEMAN™ 1500/2500 FuRNAcE /...
  • Page 4: Table Of Contents

    BLOwER FAN AND mOTOR CARE ..............17 ChImNEY mAINTENANCE ................18 END OF SEASON (ASh REmOvAL) mAINTENANCE ........18 INSTALLATION ARRANgEmENT DIAgRAmS ......... 19 – 22 PARTS NORSEmAN™ 1500 ..............24 – 25 PARTS NORSEmAN™ 2500 ..............26 – 27 Page 4 / NORSEMAN™ 1500/2500 FuRNAcE...
  • Page 5: Furnace Description & Installation Options

    When the central system thermostat calls for heat, the central system will operate by igniting the burner and turning on the blower. It is possible that both systems will oper- Page 5 VGZ-018 / 051809.0 NORSEMAN™ 1500/2500 FuRNAcE /...
  • Page 6: Locating The Furnace

    CONNECT ThIS UNIT TO A ChImNEY FLUE LARGEST). SERvINg OThER APPLIANCES. Fig. 1 – Top View Fig. 2 – SiDe View Minimum Clearances from Combustible Surfaces Minimum Clearances from Combustible Surfaces Page 6 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.0...
  • Page 7: Tools And Materials Required For Installation

    7/16” box wrench Electrical Wiring: 16 ga. AWG copper with 90° c min. DO NOT use aluminum wire or connectors. 1/2˝ conduit & connectors Furnace cement (manufacturer recommends Rutland code 78 or equivalent) Page 7 VGZ-018 / 051809.0 NORSEMAN™ 1500/2500 FuRNAcE /...
  • Page 8: Assembly Instructions

    (see figure 7). Replace junction box cover when complete. use 16 ga. AWG rated for 90° c min. 10. check operation of shaker grates with grate handle before loading fuel in furnace. Fig. 6 – Blower Assembly Page 8 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.0...
  • Page 9: Furnace Installation

    NOT use galvanized pipe for chimney connec- tions. Seal the flue pipe in the chimney with furnace cement. (chimney connections must be securely supported and connections fastened with 3 sheet metal screws at each joint.) Page 9 VGZ-018 / 051809.0 NORSEMAN™ 1500/2500 FuRNAcE /...
  • Page 10: Wiring Diagram

    NOTE: Do NOT break off jumper for low voltage. Fig. 7 – Model 1500 wiring Diagram Fig. 8 – Model 2500 wiring Diagram Page 10 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.0...
  • Page 11: Furnace Dimensions

    FURNAcE DiMENsioNs Fig. 9 – Model 1500 Dimension NOTICE: ThESE ARE PRODUCT DImENSIONS ONLY. PLEASE SEE FIgURES 1 & 2 ON PAgE 6 AND LABELS AFFIxED TO APPLIANCE FOR PROPER CLEARANCES TO COmBUSTIBLE mATERIALS. Fig. 10 – Model 2500 Dimensions Page 11 VGZ-018 / 051809.0...
  • Page 12: Chimney Connections

    Do not use makeshift com- CONNECTED wITh ANY OThER APPLIANCE. promises during installation. NEvER USE A SINgLE- wALL CONNECTION PIPE AS A ChImNEY! continued on next page Page 12 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.0...
  • Page 13: Connector Pipe Installation

    This will allow any condensation in the flue to run rigid. back into the firebox. continued on next page CORRECT wRONg wRONg Fig. 14 – Stovepipe/Flue Connections Page 13 VGZ-018 / 051809.0 NORSEMAN™ 1500/2500 FuRNAcE /...
  • Page 14 RISk OF FIRE. DO NOT OPERATE wITh FLUE DRAFT ExCEEDINg 0.05˝ wATER COLUmN (0.1 Pa). 5. After all adjustments have been made, seal the hole made for the manometer tube with furnace cement. Page 14 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.0...
  • Page 15: Operating Instructions

    3 . P R Ov I D E A I R I N TO T h E R O O m F O R PROPER COmBUSTION. continued on next page Page 15 VGZ-018 / 051809.0 NORSEMAN™ 1500/2500 FuRNAcE /...
  • Page 16: Coal Burning Tips

    LATED gASES TO BE BURNED OFF. will change and less smoke will be produced. Once the fire is well established, add coal to the center of the firebox in a conical arrangement. The high- Page 16 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.0...
  • Page 17: Blower Limit Control Settings

    Oil blower motor(s) twice a year. Add five drops of light weight (SAE 20) oil to each oiler tube. If the blower and fan accumulate moderate to heavy dust, vacuum, wipe and/or blow dust from motor housing and fan. Page 17 VGZ-018 / 051809.0 NORSEMAN™ 1500/2500 FuRNAcE /...
  • Page 18: Chimney Maintenance

    YOUR ChImNEY INSPECTED BY A qUALIFIED PERSON BEFORE USINg AgAIN. END oF sEAsoN MAiNtENANcE Remove all accumulated ash from inside the fire box and ash drawer compartment. Ash will absorb moisture and can cause corrosion. Page 18 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.0...
  • Page 19: Installation Arrangement Diagrams

    Do not use untested configurations, dangerous operating conditions or risk of fire may occur. Always have a qualified heating equipment professional install your furnace. Fig. 16 – Add-on installation Fig. 17 – Central installation Page 19 VGZ-018 / 051809.0 NORSEMAN™ 1500/2500 FuRNAcE /...
  • Page 20 NotE: to prevent damage from overheating, backdraft Dampers MUst be used and installed no closer than 18 inches to the top surface of the furnace. Fig. 19 – Add-on plenum Collector Box Page 20 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.0...
  • Page 21 NotE: to prevent damage from overheating, backdraft Dampers MUst be used and installed no closer than 18 inches to the top surface of the furnace. Fig. 21 – Add-on plenum Backdraft Flapper Page 21 VGZ-018 / 051809.0 NORSEMAN™ 1500/2500 FuRNAcE /...
  • Page 22 NotE: to prevent damage from overheating, backdraft Dampers MUst be used and installed no closer than 18 inches to the top surface of the furnace. Fig. 23 – Central Furnace installation Page 22 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.0...
  • Page 23 Page 23 VGZ-018 / 051809.0 NORSEMAN™ 1500/2500 FuRNAcE /...
  • Page 24: Parts Norseman™ 1500

    When ordering missing or replacement parts, always give the Model Number of the furnace, Part Number, and Part Description. use the illustrations and part lists provided on the following pages to identify parts. Page 24 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.2...
  • Page 25 When ordering missing or replacement parts, always give the Model Number of the furnace, Part Number, and Part Description. use the illustrations and part lists provided on the following pages to identify parts. Page 25 VGZ-018 / 051809.2 NORSEMAN™ 1500/2500 FuRNAcE /...
  • Page 26: Parts Norseman™ 2500

    When ordering missing or replacement parts, always give the model Number of the furnace, Part Number, and Part Description. use the illustrations and part lists provided on the following pages to identify parts. Page 26 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.0...
  • Page 27 When ordering missing or replacement parts, always give the model Number of the furnace, Part Number, and Part Description. use the illustrations and part lists provided on the following pages to identify parts. Page 27 VGZ-018 / 051809.0 NORSEMAN™ 1500/2500 FuRNAcE /...
  • Page 28 “FOR gOD SO LOvED ThE wORLD ThAT hE gAvE hIS ONLY BEgOTTEN SON, ThAT whOEvER BELIEvES IN hIm ShALL NOT PERISh BUT hAvE ETERNAL LIFE” jOhN 3:16 mADE IN ChINA Vogelzang International corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 Page 28 / NORSEMAN™ 1500/2500 FuRNAcE VGZ-018 / 051809.0...

This manual is also suitable for:

Norseman 2500

Table of Contents