Note For The Replacing Of Memory Ic - Toshiba MV20FK3 Service Manual

Color television/video cassete recorder
Table of Contents

Advertisement

If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
NOTE:
Initial Data setting will not be possible if clock has been set. To reset clock, either unplug AC cord and allow
at least 5 seconds before Power On.
ADDRESS DATA ADDRESS DATA ADDRESS DATA ADDRESS DATA ADDRESS DATA
00
01
02
03
04
05
06
07
08
09
Enter DATA SET mode by setting VOLUME to minimum.
1.
While holding down VOLUME button on front cabinet, press key 6 on remote control simultaneously.
2.
ADDRESS and DATA should appear as FIG 1.
3.
ADDRESS is now selected and should "blink". Using the SET + or - keys on the remote, step through the ADDRESS until
required ADDRESS to be changed is reached.
4.
Press ENTER to select DATA. When DATA is selected, it will "blink".
5.
Again, step through the DATA using SET + or - until required DATA value has been selected.
6.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
7.
Repeat steps 3 to 6 until all data has been checked.
8.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
The unit will now have the correct DATA for the new MEMORY IC.

NOTE FOR THE REPLACING OF MEMORY IC

08
0A
1C
0A
0B
90
A2
0C
99
43
0D
0D
C2
0E
00
14
0F
0A
34
10
8C
4B
11
68
51
12
5C
B2
13
53
14
27
15
00
16
32
17
05
18
9E
19
89
1A
A9
1B
02
1C
05
1D
39
Table 1
ADDRESS
DATA
INIT
00
83
0010
POWER ON
0003
PLAY/REC
Fig. 1
1E
10
28
1F
E1
29
20
BA
21
05
22
79
23
05
24
3E
25
2A
26
39
27
00
01
35

Hide quick links: