Summary of Contents for Chart Industries 11744195

  • Page 1 Chart Test Chambers CHART INDUSTRIES, INC. ISIS CHAMBER USER’S MANUAL Rev. A...
  • Page 2: Overview

    Chart Environmental Chambers Service The Chart Environmental Chambers have been designed for years of safe and dependable operation. In the event service is required, contact the nearest Chart authorized service center or contact Chart at: Chart Industries, Inc. 3505 County Road 42 West Burnsville, MN 55306 USA Phone: 1-888-877-3093 www.chartchambers.com...
  • Page 3: Safety First

    Chart Environmental Chambers This manual is intended for use by Chart, Inc. Environmental Chamber customers. It is important to read and understand the information in this manual before installing or operating the chamber system. This will result in safer operation, longer equipment life, and more effective testing.
  • Page 4 Chart Environmental Chambers Overview Symbols and statements throughout this text and their meaning: Text following this symbol needs extra attention. NOTE: Text in this format is extra information helpful to the situation. CAUTION: Text in this format is information to help avoid personal injury and/or property damage.
  • Page 5: Table Of Contents

    Chart Environmental Chambers OVERVIEW... II ERVICE ANUFACTURER ESIGN ODIFICATION DDITIONAL OPIES DESCRIPTION OF SAFETY FEATURES ...3 EMPERATURE SPECIFICATIONS AND UTILITY REQUIREMENTS ...4 ...4 ERFORMANCE ...4 YSTEM ETAILS ROGRAMMABLE ONTROL AND ...4 IMENSIONS AND TILITIES FEATURES ...5 EMPERATURE ONTROL IRCULATION LOWER :...5 NSTRUMENTS EMPERATURE...
  • Page 6 Chart Environmental Chambers 1 - C ABLE HAMBER ERFORMANCE 2 - S ...4 ABLE YSTEM ETAILS 3 - D ABLE IMENSIONS AND TILITIES 4 - L ABLE IQUID ITROGEN 5 - R ABLE EPLACEMENT HERMOCOUPLE 6 - D ABLE UARD WITCH List of Tables ...4...
  • Page 7: Safety Information

    Chart Environmental Chambers Your Chart equipment is provided with several safety systems designed to help prevent accidental damage to product and equipment, and avoid injury to personnel. Always operate this equipment in accordance with the procedures set forth in the OPERATION section of this manual. The safety systems described below should be checked at least once every 30 days, and any inoperative or questionable conditions must be corrected before resuming operation.
  • Page 8: Description Of Safety Features

    Chart Environmental Chambers Description of Safety Features On each unit, there are a number of features, which help to ensure safe operation. These features are: Temperature High/Low Limit Control: A user-programmable limit control is provided as an independent measure of safety against thermal runaway (hot or cold), which could occur from, but not limited to, the following: Programming error...
  • Page 9: Specifications And Utility Requirements

    S y s t e m Cooling Heating 2 kW (4 kW in HP model) of heat provided by open nichrome wire heating elements. Time proportional solid state control of resistive heating elements in air conditioning plenum. Programmable Control and Data Logging Controller Watlow Series 96 temperature controller.
  • Page 10: Features

    Chart Environmental Chambers Temperature Control System: Heating is accomplished with resistive electric elements, while cooling is accomplished by blowing liquid nitrogen into the chamber. The liquid nitrogen is vaporized through nozzles and the cold vapor is circulated over the products in the chamber so that liquid nitrogen does not touch the product under test.
  • Page 11: Temperature Safety Controller

    Chart Environmental Chambers the air-flow plenum and is not directly visible. The following figure is a picture of the Watlow controller: Temperature Safety Controller A temperature Hi/Lo limit control protects the chamber against thermal runaway due to a primary controller fault or control device failure. The input to the Hi/Lo limit control is a type T thermocouple.
  • Page 12: System Installation

    Chart Environmental Chambers Location The location of the chamber should be chosen with a few items in mind: The left side of the chamber has an access port, which allows passing power and data acquisition wires into the chamber and connecting to the device under test. The top side of the chamber has the control box.
  • Page 13: Liquid Nitrogen Plumbing

    Chart Environmental Chambers suction into the blower in the back wall of the chamber and discharge from the top of the chamber. Liquid Nitrogen Plumbing Along with the electrical power, bring in the LN chamber for easy access around the chamber. The connection point is at the solenoid valve on the back wall of the chamber.
  • Page 14 Chart Environmental Chambers System Installation It may be possible to run the chamber without the exhaust gas plumbed out of the building. An evaluation of the size of the room containing the chamber, as well as the ventilation system (number of air changes) must be done to determine this. If it is determined that the room is ventilated well enough to not plumb the exhaust gas out of the building, it is highly recommended to install an oxygen monitor in the vicinity of the chamber to ensure safe working conditions for all personnel.
  • Page 15: Operation

    Chart Environmental Chambers Check system functions and your understanding of the system by following these steps with an empty thermal enclosure before installing the product to be tested. 1. Verify that all utilities are on-line before operating equipment. Liquid nitrogen is required for proper cooling.
  • Page 16 Chart Environmental Chambers 2. Control Power (OFF, ON) This switch controls the 24vdc control power in the control system. If this switch is turned OFF, all control functions will be disabled. The temperature controllers are powered from a 115vac circuit, so they will remain powered up even if the control power switch is turned OFF, however no heating, cooling, etc will be able to take place.
  • Page 17: Watlow Series 96 Controller Operation

    Chart Environmental Chambers Watlow Series 96 Controller Operation NOTE: For more complete instructions on the operation of the Watlow Series 96 controller, refer to the supplied manual. All information in the Watlow controller manual takes precedence over information shown in this manual. Entering Temperature Set Points The temperature set point for the chamber is displayed on the bottom display of the Watlow controller.
  • Page 18: Air Safety Controller Operation

    Chart Environmental Chambers Heating/Cooling Indicators When the Watlow controller is applying a heat or cool signal, an LED is indicated on the front panel. The longer the particular LED is on, the more heating/cooling power is being applied. If the LED is continuously on, that indicates full heating/cooling power. If a heating signal is being applied, the LED by the number 1 will be illuminated, if a cooling signal is being applied, the LED by the number 2 will be illuminated.
  • Page 19: System Maintenance

    Chart Environmental Chambers Maintenance of this equipment should be done by a qualified technician. High voltage electrical systems, cryogenic plumbing, and mechanical systems all represent a potential for injury or death. The main power must be removed from the chamber, and the liquid nitrogen supply should be disconnected prior to servicing this equipment.
  • Page 20: Maintenance Tasks To Be Performed Every Three Months

    Chart Environmental Chambers 5. The seals and gaskets on the doors floors and ports should be inspected for adequate sealing. Remove any foreign materials that may be embedded in the gasket. Worn or damaged gasket should be replaced. 6. Check all the fasteners on the system and tighten if necessary. Maintenance Tasks to be Performed Every Three Months: 1.
  • Page 21: Replacement Parts

    Table 4 - Liquid Nitrogen Cooling Valve Parts Item Cooling solenoid valve Cooling solenoid valve for HP model Temperature Sensors Thermocouples This type T thermocouple is a rugged and shielded sensor designed to withstand the entire temperature range of the chamber.
  • Page 22: Warranty

    Chart Environmental Chambers Chart Industries, Inc. warrants the equipment and materials manufactured under this contract are in accordance with Chart Industries, Inc. specifications. If any part of said equipment or material manufactured by Chart Industries, Inc., as determined by the seller, is defective in workmanship or material, and not subjected to misuse or abuse, within 90 days from date of installation or within 120 days of invoice, whichever period is lesser, Chart Industries, Inc.