Error Codes - American DJ 3 Sixty 2R User Instructions

3 sixty 2r
Table of Contents

Advertisement

3 Sixty 2R
actual scenes that are stored in the user defined built-in programs
that are accessed in the previous step.
Rec Controller - The 3 Sixty 2R features an integrated DMX recorder.
Preprogrammed scenes can be transmitted to the fixture via any
DMX compliant controller. This function allows those scenes to be
stored in to the fixture's built-in memory and
then subsequently used to create the user-defined programs.
ADJ Products, LLC - www.adj.com - 3 Sixty 2R Instruction Manual Page 38
System Menu
3 Sixty 2R
When power is applied, the unit will automatically enter a
"reset/test" mode. This mode brings all the internal motors to a
home position. If there is an internal problem with one or more
of the motors an error code will flash in the display in the form
of "XXer", "XX" will represent a function number. For example,
when the display shows "03Er," it means there is some type of
error with the channel 3 motor. If there are multiple errors during
the start-up process they will all flash in the display. For exam-
ple: if the fixtures has errors on channel 1 and channel 3 all at
the same time, you will see the error message flash "01Er", and
"03Er repeated 5 times.
If an error does occur during the initial start-up procedure the
fixture will self-generate a second reset signal and try to realign
all the motors and correct the errors, if the errors persist after a
second attempt a third attempt will be made.
If after a third attempt all the errors have not been corrected the
fixture will make the following determinations:
1) 3 or more errors - The fixture cannot function properly with
three or more errors therefore the fixture will place itself in a
stand-by mode until subsequent repairs can be made.
2) Less than 3 errors - If the fixture has less than 3 errors, there-
fore most other functions will work properly. The fixture will
attempt to operate normally until the errors can be corrected by
a technician. The errors in question will remain flashing in the
display as a reminder of internal errors.
01Er – PAN movement error:
This message will appear after a fixture reset, if the pan-yoke's
magnetic-indexing circuit malfunctions (sensor failed or magnet
is missing) or there is a stepper motor failure (defective motor
or a defective motor IC drive on the main PCB).
03Er – TILT movement error:
This message will appear after a fixture reset, if the tilt mag-
netic-indexing circuit malfunctions (sensor failed or magnet is
ADJ Products, LLC - www.adj.com - 3 Sixty 2R Instruction Manual Page 39

Error Codes

Advertisement

Table of Contents
loading

Table of Contents