Page 1
10006 Santa Fe Springs Road Santa Fe Springs, CA 90670 USA Made in China Owner’s Manual and Operating Instructions SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual 1000 Peak Watts / 800 Running Watts 2 STROKE GENERATOR...
Champion Power Equipment manufactures Congratulations on your purchase of a and sells accessories designed to help you Champion Power Equipment generator. CPE get the most from your purchase. To find out designs and builds generators to strict more about our covers, power cables and specifications.
Manual Conventions CAUTION Manual Conventions CAUTION indicates a potentially hazardous This manual uses the following symbols to situation which, if not avoided, result in help differentiate between different kinds of minor or moderate injury. information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment.
Safety Rules Keep hands and feet away from rotating parts. Tie up long hair and remove jewelry. Safety Rules Operate equipment with guards in place. DO NOT wear loose-fitting clothing, dangling drawstrings or items that could become caught. WARNING DANGER Read this manual thoroughly before operating your generator.
Page 8
Safety Rules DANGER WARNING Fuel and fuel vapors are highly flammable and Rapid retraction of the starter cord will pull hand extremely explosive. and arm towards the engine faster than you can let go. Fire or explosion can cause severe burns or death.
Controls and Features Controls and Features Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator (1) Ground Terminal - Consult an (6) Choke Lever – Adjust lever to choke electrician for local grounding regulations.
Controls and Features Parts Included Your 42011 Two-Stroke Gasoline Powered Generator ships with the following parts: 3’ Charging Cord Spark Plug Socket 1 piece Handle Assembly 1 set Rev 42011-20090428...
Assembly 6. Slowly add fuel/oil mixture to the tank. DO NOT overfill. Allow approximately Assembly ¼ inch of space for fuel expansion. 7. Screw on the fuel cap and wipe away any Your generator requires some assembly. It spilled fuel. must be properly serviced with fuel and oil mixture before operation.
Operation 2. Obtain an Uninterruptible Power Supply (UPS) device. Operation Most UPS devices come with a rechargeable battery between the electronic equipment and power supply Generator Location source. The device buffers the voltage Please consult your local authority. In some and protects against virtually all short- areas, generators must be registered with duration voltage fluctuations.
Operation NOTE Do Not Overload Generator Starting watts can exceed three times the Capacity running watts. The values in the following table Follow these simple steps to calculate the are approximate. Refer to your tool or appliance for actual wattage consumption. running and starting watts necessary for your purposes.
Maintenance 5. Refer to the spark plug recommendation chart when replacing the plug. Maintenance 6. Carefully thread the plug into the engine. The owner/operator is responsible for all 7. Use the spark plug tool to firmly install periodic maintenance. the plug. WARNING 8.
Tampering with the governor can damage Water can enter the generator through the your generator and your electrical devices cooling slots and damage the generator and will void your warranty. CPE windings. recommends that you contact our service line at 1-877-338-0999 for all other service Use a damp cloth to clean exterior surfaces and/or adjustment needs.
Storage 5. Remove the spark plug and pour about Storage ½ ounce of oil into the cylinder. Crank the engine slowly to distribute the oil The generator should be started at least once and lubricate the cylinder. every 14 days and allowed to run for at least 6.
Your generator comes equipped with a ¾” long reach plug (19 mm) Engine Specifications Intermittent use (less than 1 hour/month) or Engine 64 cc OHV CPE colder temperatures (below 60°F) NGK B6ES or equivalent Generator Specifications Running Wattage 800 Watts...
Troubleshooting Troubleshooting Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Unit loaded during start up Remove load from unit Generator will not start; Choke in the wrong position. Adjust choke. Generator starts but runs roughly Spark plug wire loose Attach wire to spark plug Out of fuel...
Failures to due acts of God and other force Registration Card and a copy of your sales receipt majeure events beyond the manufacturer’s from one of CPE's retail locations as proof of control. purchase. Problems cause by parts that are not original Please submit your warranty registration and Champion Power Equipment parts.
Page 24
You are responsible for presenting your small off-road engine to an Authorized CPE service outlet, CPE dealer or CPE, Santa Fe Springs, Ca. as soon as a problem exists. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.
Page 25
24 consecutive months thereafter. 2. GENERAL EMISSIONS WARRANTY COVERAGE CPE warrants to the original, end-use purchaser of the new engine or equipment and to each subsequent purchaser that each of its small off-road engines is: a.
Page 26
TO OBTAIN WARRANTY SERVICE: You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc.