Troubleshooting - UltraCOOL M201A User Manual

Mobile evaporative cooler
Hide thumbs Also See for M201A:
Table of Contents

Advertisement

Available languages

Available languages

Problem
Possible Cause
Failure to
1. No electrical power to
start or no air
unit
delivery
• Fuse blown
• Circuit breaker
tripped
• Electric cord un-
plugged or damaged
2. Belt too loose or tight
3. Motor overheated
• Belt too tight
• Blower bearings dry
4. Motor locked
Inadequate
1. Insuffi cient air exhaust
air delivery
with cooler
running
2. Belt too loose
3. Pads plugged
Inadequate
1. Inadequate exhaust in
cooling
house
2. Pads not wet
• Pads plugged
• Open spots in pads
• Trough holes
clogged
• Pump not working
properly
Model
Volts
Modelo
Voltios
M201A
M301A / RM301A
M401A / RM401A
4
www.sylvane.com 1-800-934-9194

Troubleshooting

Remedy
1. Check power
• Replace fuse
• Reset breaker
• Plug in cords or
replace if damaged
2. Adjust belt tension
3. Determine cause of
overheating
• Adjust belt tension
• Oil blower bearings
4. Replace motor
1. Open windows or
doors to increase air
fl ow
2. Adjust belt tension or
replace if needed
3. Replace pads
1. Open windows or
doors to increase air
fl ow
2. Check water distribu-
tion system
• Replace pads
• Repack pads
• Clean trough and
unplug holes
• Replace or clean
pump
Specifi cations / Especifi caciones
Amperage
Speed
Ameraje
Velocidad
115
4.7
115
7.9
115
10.5
Problem
Possible Cause
Motor cycles
1. Low voltage
on and off
2. Excessive belt tension
3. Blower shaft tight or
4. Bearings dry
Noisy
1. Bearings dry
2. Wheel rubbing blower
3. Loose parts
Excessive
1. Inadequate exhaust
humidity in
house
Musty or
1. Stale or stagnate water
unpleasant
odor
2. Pads mildewed or
3. Pads not wetting
Water drain-
1. Float arm not adjusted
ing from
cooler
2. Drain assembly leak-
Water Capacity (gal)
Capacidad de Agua (galón)
2
4.8
2
9.2
2
11.3
Remedy
1. Check voltage
2. Adjust belt tension
3. Oil or replace bear-
locked
ings
4. Oil bearings
1. Oil bearings
2. Inspect and realign
housing
3. Tighten loose parts
1. Open doors or win-
dows
1. Drain pan and clean
in cooler
pads
2. Replace pads
clogged
3. Check water distribu-
properly
tion system
• Trough holes
• Clean
clogged
• Pump not working
• Replace or clean
properly
pump
1. Adjust fl oat
properly
2. Tighten nut and drain
ing
cap.
Weight (lbs.)
Peso (libras)
Dry
Operating
Seco
62
107
169
Lleno
102
184
263
110522-1

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M201A and is the answer not in the manual?

Related Products for UltraCOOL M201A

This manual is also suitable for:

M301aM401aRm301aRm401a

Table of Contents