NOTICE TO INSTALLER:
DO NOT DISCARD THIS MANUAL AFTER INSTALLATION. This manual contains important
operation, maintenance and precautionary information. Please present this manual to the
user/operator/owner after installation.
Read this manual prior to installing the water filtration system to ensure proper installation and operation.
Installation must conform to all local and state plumbing regulations and codes.
Connect the system to the cold water supply only. The water temperature cannot exceed 100°F (28°C).
Do not use with water that is microbiologically unsafe or of unknown quality without adequately
disinfecting before or after filtering through the CombiGuard System.
The CombiGuard Water Filtration System will perform as indicated with the water supply in
most areas; however, the water supply should be tested prior to installation to make
certain it meets the water criteria listed on the Combitherm specification sheet for the
oven model used. Contact Alto-Shaam service for recommendations if water does not
meet published standards.
NOTICE TO USER/OPERATOR/OWNER:
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE FOR PARTS, MAINTENANCE, OR
TROUBLE-SHOOTING. It is recommended that all personnel responsible for operation and
maintenance of this product read the precautions, operation, and maintenance sections of this manual.
INTRODUCTION:
The CombiGuard Triple-Guard Water Filtration
System will provide optimum water characteristics
to the cold water supply used in conjunction with
gas or electric Combitherm
oven/steamers. Use of the filter system will result
in improved operating efficiency, longer equipment
life, and reduced maintenance requirements.
CombiGuard is manufactured with high quality,
technologically advanced materials. Each filter
system is quality-inspected and pressure-tested prior
to shipment. Proper installation and routine
maintenance will ensure trouble-free operation for
years to come.
To obtain the maximum benefit from your filter
system, follow the simple instructions for periodic
maintenance located in this manual. Always refer to
this manual when performing a routine filter change.
Position the CombiGuard system in a suitable location. The direction of flow through the CombiGuard
unit is always left to right. Consider flow direction when determining installation location.
DO NOT mount the CombiGuard system near any source of heat.
DO NOT mount the system above any device or in any area that would be adversely affected by water.
INSTALLATION, OPERATION
®
combination
®
& MAINTENANCE MANUAL
SYSTEM SPECIFICATIONS
MAXIMUM PRESSURE
/
INLET
OUTLET CONNECTIONS
MAXIMUM TEMPERATURE
MINIMUM TEMPERATURE
SERVICE FLOW RATE
GALLON RATING
: Change the filter a minimum of every
CAPACITY
six (6) months or change the filter
when water is flowing through the
filter system under normal operating
conditions and the pressure gauge
needle on the outlet gauge enters
the "red zone. "
1.
: 125 psi (8.6 bar)
: 3/4" NPT
: 100°F (38°C)
: 35°F (2°C)
: 1.5 gpm (6 lpm)
: 15,000 gal (56,775 ltrs)
ASCOMBIGUARD205
#6464•03/05

Advertisement

loading

Summary of Contents for Alto-Shaam CombiGuard

  • Page 1 “red zone. ” Position the CombiGuard system in a suitable location. The direction of flow through the CombiGuard unit is always left to right. Consider flow direction when determining installation location.
  • Page 2: Installation Precautions

    (2) minutes. Flushing the CombiGuard system to be serviced. line removes air and any carbon particles. 4. Anchor the CombiGuard system on a wall stud or NOTE: The CombiGuard system does not suitable mounting material spanning the wall studs.
  • Page 3 CombiGuard Water Filtration System INSTALLATION, OPERATION & MAINTENANCE MANUAL INSTALLATION DRAWING DIMENSIONS 3/4" NPT Outlet: Connect to combi oven using copper or stainless steel water line. NOTE: DO NOT mount the CombiGuard System behind the combi oven or other appliance that would...
  • Page 4 It is important to periodically monitor the pressure is completely automatic provided adequate water gauge located on the CombiGuard unit. If the needle pressure is maintained. The requirements to on the gauge enters the red zone, it is usually an...
  • Page 5: Replacement Filter Cartridges

    INSTALLATION, OPERATION & MAINTENANCE MANUAL REPLACEMENT FILTER CARTRIDGES CombiGuard Triple Guard Water Filtration Systems are designed, tested, and certified with proven performance, size, and operating capacities. The use of replacement cartridges other than those specified will void warranties, certifications, and may compromise equipment protection, water quality, and cartridge life.