Cpu Unit Circuit - Sharp R-319FW Service Manual

Sharp r-319fw microwave oven service manual
Hide thumbs Also See for R-319FW:
Table of Contents

Advertisement

9. Now, the magnetron is free.
Reinstallation
1. Re-install the magnetron to waveguide flange with the
four (4) screws.
2. Insert the two (2) tabs of the chassis support to the oven
cavity front plate and the back plate.
3. Hold the chassis support to the oven cavity back plate,
oven cavity front flange, magnetron and the fan duct
with the five (5) screws.
POSITIVE LOCK
1. Disconnect the power supply cord, and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Push the lever of positive lock
5. Pull down on the positive lock
CAUTION: WHEN CONNECTING THE POSITIVE LOCK
CONNECTORS TO THE TERMINALS, CON-
NECT THE POSITIVE LOCK
LEVER FACES YOU.
1. Disconnect the power supply cord and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect wire leads from the door sensing switch and
the oven cavity front flange.
5. Disconnect the wire leads from panel components.
6. Remove the one (1) screw holding the control panel
assembly to the oven flange.
7. Slide the control panel assembly upward and remove it.
8. Now, individual components can be removed.
NOTE: 1. Before attaching a new key unit, wipe off remaining
adhesive on the control panel frame surfaces
completely with a soft cloth soaked in alcohol.
2. When attaching the key unit to the control panel
frame, adjust the upper edge and right edge of
the key unit to the correct position of control panel
frame.
1. Disconnect the power supply cord.
2. Remove turntable and turntable support from oven cavity.
3. Lay the oven on it's backside. Remove the turntable
motor cover by snipping off the material in four corners.
4. Where the corners have been snipped off bend corner
areas flat. No sharp edges must be evident after removal
of the turntable motor cover.
REMOVAL
1. Disconnect the power supply cord and then remove
®
CONNECTOR (NO-CASE TYPE) REMOVAL
®
connector.
®
connector.
®
®
SO THAT THE
CONTROL PANEL ASSEMBLY REMOVAL
TURNTABLE MOTOR REMOVAL
COOLING FAN MOTOR REMOVAL
29
4. Reconnect the wire leads to the magnetron and thermal
cut-out (MG). Refer to "PICTORIAL DIAGRAM" on page
33.
5. Re-install outer case and check that the oven is operating
properly.
CAUTION: WHEN REPLACING MAGNETRON, BE SURE
THE R.F. GASKET IS IN PLACE AND MOUNT-
ING SCREWS ARE TIGHTENED SECURELY.
Positive lock®
connector
Lever
Figure C-2. Positive lock
3. Stick the key unit firmly to the control panel frame
by rubbing with soft cloth not to scratch.
CPU UNIT
NOTE: Handle the CPU unit carefully so that the ribbon
cable does not come off. Because the ribbon cable
is glued on the LCD and the printed wiring board
only by heated paste.
Ribbon cable
5. Disconnect wire leads from turntable motor.
(See "Positive lock connector removal")
6. Remove two (2) screws holding turntable motor to oven
cavity.
7. Now the turntable motor is free.
8. After replacement use the one (1) screw to fit the
turntable motor cover.
outer case.
2. Open the door and block it open.
R-319FW
Terminal
1
Push
2
Pull down
®
connector
CPU unit

Hide quick links:

Advertisement

Table of Contents
loading