3-3. Picture Quality Adjustments

3-3-1. Preparation

1. Set in the service mode.
2. Set respective items as follows.

Adjustment Condition

DRC-MF
: DRC1250
PICTURE MODE : HI-FINE
3D-NR MODE
: OFF
ECO MODE
: OFF
WIDE MODE
: OFF
Category
SAJ
00
02
06
0C
0D
0E
0F
13
14
16
19
JGL
03
04
05
WHB
03
04
05
06
07
08
3. Connect the oscilloscope probe to the following point on the
A board.
KV-HS29M61/M90/M91, HS34M61/M90/M91, HS38M61/M90/M91
Item
Data
PIC
3F
COL
22
DYC
00
GMS
00
GMR
00
GMG
00
GMB
00
ABT
00
CLO
07
HUO
07
PIO
00
BBT
00
LML
03
SCO
07
RDR
1F
GDR
1F
BDR
1F
RCT
1F
GCT
1F
BCT
1F

Original Condition

DRC-MF
PICTURE MODE : HI-FINE
3D-NR MODE
ECO MODE
WIDE MODE
Category
Item
SAJ
00 PIC
02 COL
06 DYC
0C GMS
0D GMR
0E GMG
0F GMB
14 CLO
16 HUO
19 PIO
13 ABT
JGL
03 BBT
04 LML
05 SCO

Measurement Point

A Board CN1100 :
1 pin R100 t VR
5 pin B100 t VB
Note : After the adjustment 5-3. Picture Quality Adjustment,
these adjustment parameters must be recovered to the
original condition.
– 35 –
: DRC1250
: OFF
: OFF
: OFF
Data
50TV 50VIDEO 60TV 60VIDEO
25
(HI-Fine)
21
(HI-Fine)
00
(HI-Fine)
00
(HI-Fine)
00
(HI-Fine)
00
(HI-Fine)
00
(HI-Fine)
03
09
07
05
04
07
(TWIN)=07
00
02
00
05
RM-997
07
07

Hide quick links: