Optical Parts Disassemblies
Polarized Glass-Out/Pre-Polarized Glass
removal
1
A
Remove 4 screws
upward from the optical unit.
2
B
Remove each screw
Note: Models PLC-XU37 and XU38 have a pre-polarized
glass for the green panel is mounted in front of the polarized
glass-out (G) as Fig.7-3.
Note:
Do not replace the LCD panel
separately otherwise it can
not obtain proper picture.
Optical Unit Top removal
1
Remove 9 screws to take the Optical Unit Top off upward.
and take the LCD/Prism ass'y off
and take the glass off upward.
A
LCD Panel/
A
A
Prism Ass'y
Fig.7-
LCD Panel/Prism
Ass'y
* Glasses should be placed as the
film attached side comes to the
LCD panel side.
* Model PLC-XU37, XU38 only
1
-17-
B
Polarized
Glass-Out
LCD Panel
Fig.7-
2
Polarized Glass-Out(G)
Pre-Polarized Glass
Fig.7-
3
Optical Unit Top
Fig.8