Sharp 20R-S100S Service Manual page 8

Chassis no. sn-010
Table of Contents

Advertisement

20R-S100S
FEATURE
SERVICE
ADJUST ITEM
POSITION
M01
MS LEVEL
M02
MTS-VCO
M03
FILTER
M04
LOW SEPARATION
M05
HIGH SEPARATION
Note: Refer to the SERVICE ADJUSTMENT for each corresponding values.
Holding down both the Vol-up/Ch-down buttons on the TV set at service mode for more than 2 seconds will
automatically write the above initial values into IC2102 (IC2101).
PART REPLACED
NECESSARY
IC2001
IC201
IC2102
(IC2101)
CRT
DATA
INITIAL VALUE
RANGE
00-0F
00-3F
00-3F
00-3F
00-3F
Table - D
ADJUSTMENT
UNNECESSARY
X
X
X
X
Table - E
R2101
R2102
If using
IC2101
If using
IC2102
Table - F
ADJUSTMENT CONTENTS
0A
20
1C
20
1B
NOTES
Data is stored in IC2102 (IC2101).
The adjustment is needed to compensate for characteristics
of parts including IC201.
Holding down both the Vol-up/Ch-down buttons on the TV
set in the service mode for more than 2 seconds will
automatically write the above initial values into IC2102
(IC2101).
Adjust items related to picture tube only.
R2103
R2104
8