Sanyo DS19310 Service Manual page 31

Color television
Hide thumbs Also See for DS19310:
Table of Contents

Advertisement

2. IN THE PURITY AND CONVERGENCE ADJUSTMENTS LIST
PAGE 10
PURITY ADJUSTMENT
1. When replacing picture tube or deflection yoke, mount
deflection yoke and purity-convergence magnets assembly
properly. See Figure 1. Position the picture tube facing east
or west. Demagnetize the picture tube and receiver using
an external degaussing coil. Set receiver to Service Menu
No. 042 (no vertical sweep) while degaussing.
2. Place the yoke on tube neck fully against glass.
2a. Place the CPM on the tube neck aligning the center of
the purity magnet tabs (2 pole) over center of Focus
Gap (G3 & G4). See Figure 2.
3. Connect a color bar generator to the antenna terminal.
Switch the generator to a white field. Move yoke backward
on the neck until a uniform white field is obtained.
4. Allow 30 minutes warm up on a blank white field (high
intensity grayscale).
Note: If white field cannot be obtained, check Grayscale
Adjustments on page 6.
5. Set the picture controls to the Auto levels. Select a green
raster, either with the signal generator or by adjusting the
bias controls. If a signal generator is used for this step,
Skip to Step 10. If the bias controls will be used, go to step
6.
6. Adjust Service Menu No. 008 RB (R-Bias), No. 009 GB (G-
Bias), and No. 010 BB (B-Bias) data to 0 each.
7. Select Service Menu No. 042 (no vertical sweep).
8. Adjust the screen control counterclockwise until the
horizontal scan lines is no longer visible.
9. Select Service Menu No. 009 GB (G-Bias) and raise the
data to produce green raster.
reduce screen control slightly.
10. Pull yoke back on the tube neck to obtain three-color raster
(blue, green and red).
11. Adjust the angle between the two purity magnet tabs to
center the vertical green belt in the picture tube. Do not
rotate tabs. See Figure 3.
12. Slowly slide the deflection yoke forward until a uniform
green screen is obtained.
13. Check the purity of the red and blue screens for uniformity.
Turn off other colors to check (use bias controls) or use
generator. If necessary, readjust the yoke position until all
screens are pure.
14. If bias controls and screen control were used to set purity,
reset Grayscale and Brightness Level. Refer to Grayscale
Adjustment on page 6 and Brightness Level Adjustment on
page 7.
15. Confirm that the yoke is not tilted. Tighten the yoke
mounting screw. Adjust convergence next.
If retrace lines appear,
— 3 —
DEFLECTION YOKE
DEFLECTION YOKE
MOUNTING SCREW
Figure 1. Deflection Yoke Movement
PURITY
MAGNET
TABS
SIX-POLE
MAGNET TABS
Figure 2. Purity and Convergence Magnets
ANGLE OF MAGNET TABS
MAGNET TABS
Figure 3. Adjusting Magnet
RUBBER
WEDGE
FOUR-POLE
MAGNET TABS
ANGLE
OF TABS
FOCUS GAP
(G3-G4)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents