Sharp R-305CW Supplemental Service Manual page 8

Table of Contents

Advertisement

R-305CW
PROCEDURE
LETTER
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
(HIGH VOLTAGES ARE PRESENT AT THE HIGH VOLTAGE TERMINAL, SO DO NOT ATTEMPT TO
MEASURE THE FILAMENT AND HIGH VOLTAGE.)
J
KEY UNIT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable
is making good contact, verify that the door sensing switch (stop switch) operates properly; that is the
contacts are closed when the door is closed and open when the door is open. If the door sensing
switch (stop switch) is good, disconnect the flat ribbon cable that connects the key unit to the control
unit and make sure the door sensing switch is closed (either close the door or short the door sensing
switch connecter). Use the Key unit matrix indicated on the control panel schematic and place a
jumper wire between the pins that correspond to the STOP/CLEAR pad making momentary contact.
If the control unit responds by clearing with a beep the key unit is faulty and must be replaced. If the
control unit does not respond, it is faulty and must be replaced. If a specific pad does not respond,
the above method may be used (after clearing the control unit) to determine if the control unit or key
pad is at fault.
5. Reconnect all leads removed from components during testing.
6. Re-install the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
L
COMPU DEFROST TEST
WARNING : The oven should be fully assembled before following procedure.
(1) Place one cup of water in the center of the turntable tray in the oven cavity.
(2) Close the door, touch the " COMPU DEFROST " pad twice.
(3) Touch the Number pad " 5 " and then touch the " START " pad.
(4) The oven is in Compu Defrost cooking condition.
(5) The oven will operate as follows
(6) If improper operation is indicated, the control unit is probably defective and should be checked.
TEST PROCEDURES
G 8
G 7
5
4
G 9
0
9
G10
Power
G11
Level
Stop
G12
BEVERAGE
Clear
G13
G14
WEIGHT
1ST STAGE
LEVEL
TIME
0.5lb
60%
45sec.
COMPONENT TEST
G 6
G 5
G 4
G 3
MINUTE
2
1
3
PLUS
Fresh
8
7
6
vegetables
Timer
Casserole
POPCORN
START
DEFROST
Clock
Baked
potatoes
2ND STAGE
LEVEL
TIME
40%
20sec.
6
G 2
G 1
Rolls/
muffins
COMPU

Hide quick links: