Section 5: Diagrams; Circuit Boards Location; Printed Wiring Board And Schematic Diagram Information - Sony KV-27FS210 Service Manual

Ba-5d chassis trinitron color television
Hide thumbs Also See for KV-27FS210:
Table of Contents

Advertisement

Available languages

Available languages

5-1. CIRCUIT BOARDS LOCATION

C Board
V Board
HR Board
BD Board
P Board
GK Board
(All Except KV-29FA210)
5-2. PRINTED WIRING BOARD AND
SCHEMATIC DIAGRAM INFORMATION
All capacitors are in µF unless otherwise noted. pF : µµF 50V or less are
not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specified.
All resistors are in ohms. kΩ=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating electrical
power, is as follows:
Pitch : 5mm
Rating electrical power :
/
W in resistance,
/
W and
1
1
1
4
10
: nonflammable resistor
: fusible resistor
: internal component
: panel designation and adjustment for repair
: earth ground
: earth-chassis
All variable and adjustable resistors have characteristic curve B, unless
otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10MΩ digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production tolerances.
All voltages are in V.
S : Measurement impossibility.
: B+line
: B-line (Actual measured value may be different).
: signal path (RF)
Circled numbers are waveform references.

SECTION 5: DIAGRAMS

TK Board
A Board
(KV-29FA210 Only)
/
W
1
4
/
W in chip resistance.
8
The components identified by shading and
only with part number specified.
The symbol
side of the board. Replace only with fuse of the same rating as marked.
Les composants identifies per un trame et une marque
securite. Ne les remplacer que par une piece portant le numero specifie.
Le symbole
fusible de meme yaleur, comme maque.
The components identified by X in this basic schematic diagram have
been carefully factory-selected for each set in order to satisfy regulations
regarding X-ray radiation. Should replacement be necessary, replace
HU Board
only with the value originally used.
When replacing components identified by Y, make the necessary
adjustments as indicated. If the results do not meet the specified value,
change the component identified by X and repeat the adjustment until
the specified value is achieved. (Refer to Section 3: Safety Related
Adjustments on Page 16.)
When replacing the parts listed in the table below, it is important to
perform the related adjustments.
�����������������
���������
������������������������
�������������������������
������������������������
����������
����������
������������
REFERENCE INFORMATION
RESISTOR
: RN
METAL FILM
: RC
SOLID
: FPRD NONFLAMMABLE CARBON
: FUSE NONFLAMMABLE FUSIBLE
: RW
NONFLAMMABLE WIREWOUND
: RS
NONFLAMMABLE METAL OXIDE
: RB
NONFLAMMABLE CEMENT
:
ADJUSTMENT RESISTOR
COIL
: LF-8L MICRO INDUCTOR
— 30 —
KV-27FS210/29FA210/32FS210/36FS210
!
symbol are critical for safety. Replace
indicates a fast operating fuse and is displayed on the component
indique une fusible a action rapide. Doit etre remplace par une
��������������
������������
����������
CAPACITOR
: TA
TANTALUM
: PS
STYROL
: PP
POLYPROPYLENE
: PT
MYLAR
: MPS
METALIZED POLYESTER
: MPP
METALIZED POLYPROPYLENE
: ALB
BIPOLAR
: ALT
HIGH TEMPERATURE
: ALR
HIGH RIPPLE
!
sont critiques pour la

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents