Sharp R-308CK Service Manual page 21

Table of Contents

Advertisement

Pin No.
Signal
I/O
11-13
P57-P55
OUT
14
CNTR0
OUT
15
P53
OUT
16
P52
OUT
17-18
P51-P50
OUT
19-20
P47-P46
OUT
21
P45
IN
22
P44
IN
23
P43
IN
24
INT0
IN
25
P41
IN
26
P40
IN
27
RESET
IN
28-29
P71-P70
OUT
30
XIN
IN
31
XOUT
OUT
32
VSS
IN
Terminal not used.
Signal to sound buzzer (2.0 kHz).
A: key touch sound.
B: Completion sound.
Oven lamp, fan motor and turntable motor driving signal
To turn on and off shut off relay (RY1). The
square waveform voltage is delivered to the
RY1 driving circuit and RY2 control circuit.
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2). The
signals holds "L" level during microwave cook-
ing and "H" level while not cooking. In other
cooking modes (variable cooking) the signal
turns to "H" level and "L" level in repetition
according to the power level.
Terminal not used.
Terminal not used.
Signal coming from touch key.
When either G12 line on key matrix is touched, a corresponding signal out of P20 - P27
will be input into P45. When no key is touched, the signal is held at "H" level.
Signal similar to P45.
When either G11 line on key matrix is touched, a corresponding signal will be input into P44.
Signal similar to P45.
When either G10 line on key matrix is touched, a corresponding signal will be input into P43.
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing of LSI.
Signal similar to P45.
When either G9 line on key matrix is touched, a corresponding signal will be input into P41.
Connected to GND through the pull-down resistor R90.
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied. Temporarily set
"L" level the moment power is applied, at this time the LSI is reset. Thereafter set at "H"
level.
Terminal not used.
Internal clock oscillation frequency input setting.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit with
respect to XIN terminal.
Internal clock oscillation frequency control output.
Output to control oscillation input of XOUT.
Power source voltage: -5.0V.
VC voltage of power source circuit input.
19
Description
0.1 sec.
A
2.0 sec.
B
16.7 msec.
During cooking
OFF
P-HI
ON
OFF
P-70
ON
(ON and OFF times for other power level.)
R -308CK
R-308CW
R -310CK
R -310CW
H : GND
L : -5V
H : GND
L : -5V
H : GND
L : -5V
H : GND
L : -5V
OFF
H : GND
24 sec.
8 sec.
L : -5V
H : GND
L : -5V
16.7 msec.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-310ckR-310cwR-308cw