GENERAL

The F114 and F115 Ceiling Surface Mounted Media Air
Cleaners use direct-drive, forward curve, blower/motors with
95% D.O.P. particle or HEPA filters to remove airborne
contaminants. The air cleaners are designed for use in
restaurants, conference rooms, lounges and offices where
overhead air cleaning is required. They provide their own air
circulation, so the air cleaners can be used in any situation
that requires the reduction of contamination from an enclosed
area.
The Honeywell Trademark is used under license from Honeywell
Intellectual Properties, Inc. by Air-Pure Systems.
Honeywell International Inc. makes no representations or warranties
with respect to this product.
F114
F115

FEATURES

• High Efficiency Particulate AIR (HEPA) filter models are
99.97% efficient and the D.O.P. particle filter models are
95% efficient at 0.3 micron particles. Both models are
more efficient on particles smaller and larger.
• F114 two-speed, direct-drive, forward curve, motor/blower
models deliver up to 325 cfm (550 m3/hr).
• F115 single speed models deliver up to 600 cfm
(1020 m3/hr) .
• Select models include CPZ™ disposable canisters for
odor control.
• Light colored covers complement the ceiling finish.
• Available in 120 Vac, 60 Hz or 220-240 Vac,
50/60 Hz models.
READ AND SAVE THESE
INSTRUCTIONS
General .............................................................................. 1
Features ............................................................................ 1
Specifications .................................................................... 2
Ordering Information ......................................................... 2
Planning the Installation ................................................... 3
Installation ......................................................................... 4
Operation ........................................................................... 5
Service ............................................................................... 5
Parts List ........................................................................... 6
Warranty ............................................................................. 10
PRODUCT DATA
Contents

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell F115

  • Page 1: Table Of Contents

    • F114 two-speed, direct-drive, forward curve, motor/blower models deliver up to 325 cfm (550 m3/hr). • F115 single speed models deliver up to 600 cfm (1020 m3/hr) . • Select models include CPZ™ disposable canisters for odor control.
  • Page 2: Specifications

    F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS SPECIFICATIONS IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. This product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed.
  • Page 3: Planning The Installation

    F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS Dimensions: See Fig. 1 and 2 for dimensions. 37-1/2 (952) 34-1/8 (867) 28-7/8 (733) 1-1/4 (31) 3/8 IN. (10) DIAMETER POWER INPUT POINT MOUNTING HOLES (2) Fig. 1. Approximate dimensions of F114 in in.
  • Page 4: Installation

    F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS IMPORTANT When selecting a location, make sure the air cleaner is secured to ceiling load-bearing supports or joists. If installing on a T-grid drop ceiling, secure the air cleaner to the true ceiling.
  • Page 5: Operation

    In areas with ceilings up to 10 feet high, the F114 models can effectively clean an area of 200 to 600 sq ft (18 to 54 sq m). The F115 models can clean a 600 to 1200 sq ft (54 to 108 sq m) area.
  • Page 6: Parts List

    F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS CAUTION Electrical Shock Hazard. Power source can shock. • Turn off the power to the air cleaner when cleaning or servicing. • Stand on a stable platform when working with the air cleaner.
  • Page 7: Revised

    F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS PLENUM Fig. 6. Exploded view of F114 Ceiling Surface Mounted Media Air Cleaner components. (EARLY MODELS 11 AND 12 0NLY) M12711 68-0201-2 Revised 11-07...
  • Page 8 F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS Table 3. F115 Ceiling Surface Mounted Media Air Cleaner Parts List. t l i f l i f t l i d l i 68-0201-2 Revised 11-07 r i u c i t...
  • Page 9 F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS Fig. 7. Exploded view of F115 Ceiling Surface Mounted Media Air Cleaner components. INSPECTION PLENUM PLATE ACCESS PLATE M12712 68-0201-2 Revised 11-07...
  • Page 10: Warranty

    LIMITED TWO-YEAR WARRANTY Air-Pure Systems warrants its air cleaner products to be free from defects in workmanship or materials under normal use and service, for a period of two (2) years from the date of purchase by the originial end-user. If at anytime during the warranty period the product is defective or malfunctions, Air-Pure Systems, through the distributor or dealer, from which the product was purchased, or through an authorized warranty repair station, shall at Air-Pure Systems option, replace or repair the defective product or component.