Download Print this page
X10 XPD3 User Manual
X10 XPD3 User Manual

X10 XPD3 User Manual

Incandescent dimmer switch - receiver

Advertisement

Quick Links

Incandescent Dimmer Switch - Receiver
Single-Pole Switch
Switched Leg
to Light
Description:
The XPD3 is an Incandescent, decorative-style, dimming, Single-Pole/3-Way Master Wall Switch rated for 40-500watts.
It can handle loads as follows: Incandescent Bulbs only (i.e. 120V Standard or 120V Halogen). The decorative paddle permits local operation of
ON/OFF and Bright/Dim of the lighting load. The Power Cutoff Switch is provided for bulb changing. The X10 Address Code Dials for setting the
Letter Code and Number Code are located behind the paddle.
Specific Requirements:
120VAC, 40-500W Incandescent ONLY. Lamps rated below 40W may flicker and/or operate erratically.
DO NOT use with: Fluorescent Lighting, Low Voltage Lighting (which use Inductive Transformers), ceiling fan motors, etc.
Optional / Supplementary Devices & Modules:
XPDP-AL - Almond Rocker in Pkg of 10ea.
XPSS - Slave Switch for existing 3-Way Installations. Uses XPSP-AL Almond rockers.
XPT2D - Alternate Slave Switch (Transmitter) for existing and creating new 3-Way/4-way Installations.
X10 Protocol:
House Code Dial - Letters A-P (default "A")
Each X10 Receiver Module is set to a unique Unit Number or to an identical Unit Number as desired.
Each X10 Controller operating a specific set of Receiver Modules must be set to the same Letter Code as the Receivers they are controlling.
Responds to ALL LIGHTS ON command. Full Dimming capability with Incandescent lighting.
Electrical Protocol:
Nearly all residential homes are wired SPLIT-PHASE. Each 120V Phase is NOT directly connected with the other 120V phase. If after installation,
an X10 Receiver does not respond to a remote Controller, then check to ensure that the breaker serving the X10 Receiver is on the same phase as
the Controller. If not, the breaker can be changed to the opposite phase. An alternative solution is recommended, to install a Phase Coupler for
improving remote communications throughout the home. See www.x10pro.com, then select Technical Support and PLC Troubleshooting.
Installation: for Single-Pole operation
1. Turn power OFF at Circuit Breaker.
2. Pull-out the existing wall switch from the switch box.
3. On the XPD3, Cap off the RED wire, it will not be used in this install.
4. Remove the existing wall switch. Two wires remain, one is HOT, the other goes to the light/load. They may be the same color.
5. With Breaker ON, determine which protruding wire is HOT. Use a voltmeter and measure between ground and each wire individually.
One will read 120V, the other 0V.
6. With Breaker OFF, connect the HOT wire to the BLACK wire, connect the Light/Load wire to the BLUE wire.
7. Re-check all connections, Turn power ON at Circuit Breaker. Slide the Power Cutoff Switch to ON position.
8. Press rocker paddle once, the light should turn ON. Press & Hold to Dim the light/load. Press paddle again, the light should turn OFF.
9. You are now ready to control the switch with an X10 Remote Control Module: Desktop, Wireless Handheld, Security Panel, etc. The default
address is "A1". If you wish to change the Address Code, the Code Dials are behind the paddle. Remove the paddle with a small flat screwdriver
applied to the side of the paddle at the center fulcrum point. Insert screwdriver in the small gap space between switch plate and paddle and flip the
paddle up from its side.
10. Attach the switch cover plate.
Soft Start On and Fade Off plus Bright / Dim Control:
On/Off - A short paddle press causes the Switch to come on at full dim and fade up to the full intensity, another short paddle press causes the
Switch to fade off (brightening to full intensity and fading to full off takes approx 3 seconds each direction).
Dimming from ON - Press and hold to achieve the dim level desired then release. When released, the direction of dimming is toggled, (i.e.
next press and hold will cause the switch to brighten). A short paddle press from any dimmed level will fade off the Switch. A dimmed Switch
will resume the level of intensity when turned back on
Note: If you would like the Switch to always resume full intensity when turned on, then press and hold the paddle until the Switch attains full
brightness before releasing. Then a short paddle press will fade off.
Additionally, any X10 Controller can remotely operate the full functions of the Switch.
Tampa, FL 33542
A
1
A
Blue
1
OFF
ON
XPD3
Master
Unit Number Dial - Numbers 1-16 (default "1")
(i.e. if dimmed to 50% then turned off, the Switch will resume at 50% when turned back on).
Dials Behind
Rocker
Red
No Connection
(CONTROL)
HOT
Black
(Black)
Power
Cutoff
Switch
XPD3_04_05/08
Technical Support: (800) 832-4003
XPD3

Advertisement

loading

Summary of Contents for X10 XPD3

  • Page 1 Nearly all residential homes are wired SPLIT-PHASE. Each 120V Phase is NOT directly connected with the other 120V phase. If after installation, an X10 Receiver does not respond to a remote Controller, then check to ensure that the breaker serving the X10 Receiver is on the same phase as the Controller.
  • Page 2 ON. Press the Slave Switch paddle again, and the light should turn OFF. 12. You are now ready to control the switch with an X10 Remote Control Module: Desktop, Wireless Handheld, Security Panel, etc. The default address is "A1".
  • Page 3 OFF. Additionally you can press the DIM or Brighten rocker on the alternate XPT2D Transmitter to control intensity after you turn the load on. 11. You are now ready to control the switch with an X10 Remote Control Module: Desktop, Wireless Handheld, Security Panel, etc. The default address is "A1"...
  • Page 4 6. Press switch paddle once, the light should turn ON. Press paddle again, the light should turn OFF. 7. You are now ready to control the switch with an X10 Remote Control Module: Desktop, Wireless Handheld, Security Panel, etc. The default address is "A1".