Troubleshooting - CentralPneumatic 68019 Owner's Manual

18 gauge 2-in-1 air nailer/stapler
Table of Contents

Advertisement

Troubleshooting

problem
Insufficient
1. Not enough air pressure.
fastener depth.
2. Incorrect lubrication or
not enough lubrication.
3. Blocked air inlet screen
(if equipped).
4. Mechanism contaminated.
Fasteners drive
1. Incorrect tool depth setting.
too deeply.
2. Too much air pressure.
Tool cycles
1. Jammed fastener.
without firing
fastener.
2. Tool empty.
3. Incorrect fasteners used.
4. Magazine dirty or not
lubricated properly.
5. Insufficient air flow.
Frequent
Incorrect nail / staple type.
jamming.
Severe air
1. Cross-threaded housing
leakage.
components.
(Slight air leakage
is normal,
2. Loose housing.
especially on
older tools.)
3. Damaged valve or housing.
4. Dirty, worn or damaged valve.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect air supply before service.
Page 16
possible causes
For technical questions, please call 1-800-444-3353.
Likely Solutions
1. Check for loose connections and make sure that
air supply is providing enough air pressure (PSI) to the
tool's air inlet. Do not exceed maximum air pressure.
2. Lubricate using air tool oil and grease
according to directions.
3. Clean air inlet screen of buildup.
4. Have qualified technician clean and lubricate
mechanism. Install in-line filter in air supply
as stated in Initial Set Up: Air Supply.
1. Adjust depth setting, if available.
2. Reduce air supply pressure (PSI).
1. Clear jammed fastener according to
Clearing Jams instructions.
2. Reload with correct fasteners.
3. Empty, then reload with correct fasteners.
4. Clean and lubricate magazine and pusher.
5. Check for loose connections and make sure that
air supply is providing enough air flow (CFM)
and pressure (PSI) to the tool's air inlet.
Do not exceed maximum air pressure.
Confirm nail / staple collation type, diameter, angle,
gauge, crown, type, and length. Correct as needed.
1. Check for incorrect alignment and uneven gaps.
If cross-threaded, disassemble and
replace damaged parts before use.
2. Tighten housing assembly. If housing cannot
tighten properly, internal parts may be misaligned.
3. Replace damaged components.
4. Clean or replace valve assembly.
Item 68019

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Centralpneumatic