Job Name/Location:
Date:
PO No.:
Architect:
Engr:
Rep:
(Company)
LMN096HVT
Flex Multi‐Split Standard
9,000
Btu/h Indoor Unit
Performance:
Nominal Capacity (Btu/h)
Cooling Nominal Test Conditions:
Indoor:
80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB
Electrical:
Power Supply (V/Hz/Ø)
Rated Amps (A)
Piping:
Liquid Line (in, OD)
Vapor Line (in, OD)
Drain OD, ID (in)
Temperature Sensor
Max Length Each Pipe (ft)
Max Elevation between ODU and IDU (ft)
Max Elevation between IDU and IDU (ft)
Controls Features:
•4‐Way auto swing
•Inverter
•24‐Hour on/off mer
(variable speed fan)
•Auto opera on
•Jet Cool/Jet Heat
(artificial intelligence)
•Plasma air purifying system
•Auto restart
•Self‐cleaning indoor coil
•Chaos wind
•Sleep mode
Optional Accessories:
PI485 ‐ PMNFP14A0
7‐Day Programmable Controller (Black) ‐ PQRCVSL0
7‐Day Programmable Controller (White) ‐ PQRCVSL0QW
Simple Controller with Mode (Black) ‐ PQRCVCL0Q
Simple Controller with Mode (White) ‐ PQRCVCL0QW
Simple Controller without Mode (Black) PQRCHCA0Q
Simple Controller without Mode (White) ‐ PQRCHCA0QW
AC Smart II ‐ PQCSW320A1E
ACP without DIgital I/O ‐ PQCPA11A03
ACP with Digital I/O ‐ PQCPB11A0E
LonWorks Gateway ‐ PQNFB16A1
BACnet Gateway ‐ PQNFB17B0
For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lg‐dfs.com
For:
File
Approval
GC:
Mech:
(Project Manager)
9,000
Heating Nominal Test Conditions:
Indoor:
70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
208‐230/60/1
0.20
1/4
3/8
13/16, 5/8
Thermistor
82
49.2
24.6
Tag #:
Resubmit
Other
Entering Mixed Air:
Cooling (°F DB)
Heating (°F DB)
Unit Data:
Refrigerant Type
Refrigerant Control:
Sound Pressure H/M/L (±3 dB(A))
Primary Filter
Secondary Filter
Net Unit Weight (lbs)
Shipping Weight (lbs)
Communication Cable (No x AWG)
Fan:
Type
Quantity
Motor/Drive
Airflow Rate H/M/L (CFM)
Dehumidification Rate (pts/h)
Standard Features:
•Limited Warranty with LG Cer fied Installa on
•Limited Two Year Func onal Parts Warranty
Notes:
1.See Engineering Manual for sensible and latent capaci es.
2.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
3.All communica on cable to be minimum 18 AWG, 2‐conductor, stranded, shielded and
must comply with applicable local and national code.
4.Power wiring cable size must comply with the applicable local and na onal codes.
5.This unit comes with a dry nitrogen charge.
6.This data is rated 0 above sea level, with 24.6 of refrigerant line per indoor unit and
a 0 ft level difference between outdoor and indoor units. All capacities are net with a
combination ratio between 95 – 105%.
7.Must follow installa on instruc ons in the applicable LG installa on manual.
PQWRHDF0
54‐73
61‐86
R410A
33/30/27
Washable Pre‐filter
Plasma
4 x 18
Cross Flow
Brushless Digitally Controlled/Direct
247/230/212
DFS‐SB‐AD‐018‐US 012M17
Page 1 of 2
EEV
24.5
26.4
1
2.3
Need help?
Do you have a question about the LMN096HVT and is the answer not in the manual?