Wall hung gas boiler for
central heating supply (20 pages)
Summary of Contents for bsg savio plus combi
Page 1
Savio PLUS COMBI WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY Please Read Instructions Carefully Save for Future Reference WARNING: If the information in this manual is not followed exactly, a fi re or explosion may result causing property dam- age, personal injury or loss of life.
Page 2
CSA 4.9 and is CSA compliant. This SAVIO Plus Combi has a 2 year warranty on the boiler, and 10 years on the heat exchanger a copy of which is provided with the boiler. Please be sure to return the warranty registration card as the warranty will be void without your boiler’s serial numbers (located on the ratings label affi...
Instructions for Use 11-14 Warnings Refi lling Procedure Lighting/Operation Instruction Central Heating Circuit Temp. 12-13 Extinguishing Instructions Domestic Hot Water Temperature Useful Advice 15-17 Central Heating Frost Protection Periodic Maintenance External Cleaning Operational Faults 16-17 Warranty SAVIO PLUS COMBI USER MANUAL...
Caution: Do not use this boiler if any part has been under water. Immediately call a qualifi ed service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water. SAVIO PLUS COMBI USER MANUAL...
Page 5
VACATE THE PREMISES IMMEDIATELY AND CONTACT A QUALIFIED HEATING SERVICE COMPANY OR THE GAS COMPANY OR THE FIRE DEPARTMENT. ONLY QUALIFIED, LICENSED SERVICE CONTRACTORS SHOULD PERFORM WORK ON YOUR SAVIO SAVIO PLUS COMBI BOILER. SAVIO PLUS COMBI USER MANUAL...
- B149 Installation Codes E. ANSI/ASME - CSD-1 The above codes are available from: National Fire Protection Association (NFPA) CSA International Battery March Park 8501 E. Pleasant Valley Road Quincy, Massachusetts, 02269 Cleveland, OH 44134-5575 http://www.nfpa.org http://www.csa-international.org SAVIO PLUS COMBI USER MANUAL...
General Information The SAVIO Plus Combi is a high effi ciency condensing, wall mounted gas boiler which pro- vides central heat. The boiler features a gas valve which modulates the energy input from 49,476 BTU/h to 116,008 BTU/h. The boiler is shipped fully assembled. All units are pressure and combustion tested at the factory prior to shipping.
D.h.w. ΔT 30 K gal/h Nominal heat fl ow rate 116.0 D.h.w. ΔT 35 K gal/h Nominal heat fl ow rate D.h.w. ΔT 40 K gal/h 110.2 (2000/4500ft) Min Exhaust temperature °F Max Exhaust temperature °F SAVIO PLUS COMBI USER MANUAL...
C C.h. supply copper pipe D C.h. return copper pipe E C.h PRV discharge copper pipe F D.h.w. hot water outlet pipe G D.h.w. cold water inlet pipe H Condensate drain connection area Figure 3.3 SAVIO PLUS COMBI USER MANUAL...
Lack of burner ignition (no ignition signal from the full sequence ignition device) Ignition gas pressure adjustment Minimum gas pressure adjustment Flashing lamp, alone Flashing lamp, al- Lamp OFF Lamp ON or simultaneously ternate with another with another lamp. lamp 10 SAVIO PLUS COMBI USER MANUAL...
fi tted to the boiler. You may also fi nd it necessary to vent air from your heating circuit using the installed vents, however be aware that excessive venting will cause the pressure in the system to drop. Always ensure that the pressure gauge is set at the required pressure. SAVIO PLUS COMBI USER MANUAL...
Page 12
These adjustments must be carried out by a qualifi ed person; there- fore we advise you to contact your install- Figure 5.3 er or Service Agent. 12 SAVIO PLUS COMBI USER MANUAL...
Shut off the gas supply cock connected to the gas inlet pipe and the cock connected to the supply cold water inlet pipe (see section 3.3 for pipes) • Empty the water circuit, if necessary, as shown in the installation, operation and service instructions manual in the maintenance section. SAVIO PLUS COMBI USER MANUAL...
If the maximum fl ow rate of the domestic hot water is too high for a suffi cient temperature to be reached, it is advisable to have a suitable fl ow rate limiter installed by an Authorised Assistance Technician. 14 SAVIO PLUS COMBI USER MANUAL...
• fi lling up of the central heating circuit; • bleeding of air from the central heating system; • general check of the appliance’s operation. • check the condensate trap SAVIO PLUS COMBI USER MANUAL...
It is necessary to fi ll up the appliance with water again, so as to raise the pressure to an adequate level as described in the section 5.2 of this manual. • If fi lling up with water has to be done very frequent, have the system checked for leaks. 16 SAVIO PLUS COMBI USER MANUAL...
Authorised Service Person. In case of problems other than those mentioned here, switch off the boiler, as described in Section 5.6 on page 14 and call a competent and responsible service person. SAVIO PLUS COMBI USER MANUAL...
Protection, fi ll in and mail this card, within 1 year of installation to the address listed below NAME:____________________________________ ADDRESS:____________________________ CITY:______________________ STATE:________ ZIP:______________ BOILER SERIAL NO.: _______________________ DATE OF INSTALL:_____________________ NAME OF INSTALL CO.:_____________________ ADDRESS:____________________________ CITY:______________________ STATE:________ ZIP:____________ RETURN TO: BOYERTOWN, FURNACE CO. PO Box 100 BOYERTOWN, PA 19512 1-610-369-1450 18 SAVIO PLUS COMBI USER MANUAL...
Need help?
Do you have a question about the savio plus combi and is the answer not in the manual?
Questions and answers