WIRING DIAGRAM

RANSFORMER
TRANSFORMER
120/24 VAC
120/24 VAC
24VAC
24VAC
COM
COM
W/BK
W/BK
BK/W
BK/W
W/BK
W/BK
BK/W
BK/W
BK
BK
W
W
G
G
F
F
F
F
CAT-5 CABLES
CAT-5 CABLES
J12 or J13
J12 or J13
J20 or J21
J3
J3
(External Comm) (Internal Comm)
(External Comm) (Internal Comm)
1
2
MODULATING
MODULATING
3
CONTROL BOARD II
CONTROL BOARD II
J1
J1
(MCB-II)
(MCB-II)
1
2
SEE MCB-II DETAIL A
SEE MCB-II DETAIL A
3
8
J8
OFF
OFF
2
3
SW1
SW1
1
1
J7
J7
ON
1
2
4
DS1 RED LED (ON FOR
DS1 RED LED (ON FOR
5
BLOWN F1 FUSE)
BLOWN F1 FUSE)
9
J9
F1-7.5A
F1-7.5A
(24VAC)
(24VAC)
3
4
SEE MCB-II DETAIL B
SEE MCB-II DETAIL B
11
J11
1
2
ON
ON
OFF
OFF
17
J17
1
1
SW2
SW2
1
2
3
4
DS2 MAIN MICRO
DS2 MAIN MICRO
5
YELLOW LED (2 HERTZ
YELLOW LED (2 HERTZ
6
FLASH NORMAL)
FLASH NORMAL)
J5
J5
DS3 FLAME MICRO
DS3 FLAME MICRO
YELLOW LED (2 HERTZ
YELLOW LED (2 HERTZ
1
1
FLASH NORMAL)
FLASH NORMAL)
2
2
3
3
4
4
5
5
6
6
USER INTERFACE MODULE
USER INTERFACE MODULE
CAT-5 CABLE
CAT-5 CABLE
R (+24VDC)
BL (RPM FEEDBACK)
J20 or J21
J24
J24
1
1
2
2
6
6
7
7
J2
J2
BK
BK
1
1
W
W
2
2
J18
J18
BK
BK
1
1
W
W
ON
2
2
J19
J19
BK
BK
1
1
W
W
2
2
R
R
J16
J16
J23
J23
CONFIGURATION KEY
BK
BK
1
1
R
R
2
2
J4
J4
BK/W – POWER ACC 24VAC
1
1
W/G – POWER ACC PROVER
2
2
W/BK – POWER ACC 24VAC RTN
3
3
BK/W
BK/W
4
4
R/G
R/G
5
5
W/BK
W/BK
6
6
BK/W – ALARM 24VAC
7
7
W/BK – ALARM 24VAC RTN
8
8
P1
P1
3 2 1
3 2 1
C1
C1
3 2 1
3 2 1
3 2 1
3 2 1
BK/W
BK/W
W/BK – 24VAC RTN
W/BK – 24VAC RTN
W/BK – 24VAC RTN
W/BK – 24VAC RTN
G
G
R/G – LWCO INPUT
R/G – LWCO INPUT
BK/W – 24VAC
BK/W – 24VAC
(UIM)
(UIM)
BLOWER
BLOWER
ST1
ST1
1
1
2
2
ST2
ST2
3
3
1 2 3 5
1 2 3 5
R (+24VDC)
BL (RPM FEEDBACK)
Y/R (0-10VDC COMMAND)
Y/R (0-10VDC COMMAND)
BK/W (0-10VDC RTN)
BK/W (0-10VDC RTN)
BK
BK
A
A
PUMP RELAY
PUMP RELAY
NO
NO
COM
COM
IGNITER
IGNITER
BK
BL
Y
SPLICES
SPLICES
R
R
CONFIGURATION KEY
BK/W – POWER ACC 24VAC
W/G – POWER ACC PROVER
W/BK – POWER ACC 24VAC RTN
BK/W – ALARM 24VAC
W/BK – ALARM 24VAC RTN
LWCO BOARD
LWCO BOARD
LWCO BOARD
LWCO BOARD
R
R
L1
L1
L1
L1
LLCO
LLCO
LLCO
LLCO
BK/W
BK/W
COM
COM
COM
COM
L2
L2
L2
L2
G
G
G
G
G
G
NO
NO
NO
NO
R/G – LWCO INPUT
R/G – LWCO INPUT
BK/W – 24VAC
BK/W – 24VAC
9
LEGEND
LEGEND
120VAC WIRING
120VAC WIRING
LOW VOLTAGE WIRING
LOW VOLTAGE WIRING
CAT-5 COMM CABLE
CAT-5 COMM CABLE
AVAILABLE OPTION
AVAILABLE OPTION
NOTE1: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED
NOTE1: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED
WITH THE APPLIANCE MUST BE REPLACED, REPLACE
WITH THE APPLIANCE MUST BE REPLACED, REPLACE
WITH EQUIVALNET GAUGE WIRE, INSULATION TYPE
WITH EQUIVALNET GAUGE WIRE, INSULATION TYPE
105°C, 600 VOLTS.
105°C, 600 VOLTS.
NOTE2: UNIT MAY HAVE ALL, SOME, OR NONE OF
NOTE2: UNIT MAY HAVE ALL, SOME, OR NONE OF
THE OPTIONS.
THE OPTIONS.
NOTE3: VW UNITS COME EQUIPPED WITH PUMP, VB
NOTE3: VW UNITS COME EQUIPPED WITH PUMP, VB
UNITS DO NOT.
UNITS DO NOT.
Part of J-BOX
Part of J-BOX
BK
BK
C
C
W
W
D
D
G
G
E
E
BK
BK
B
B
GAS VALVE
GAS VALVE
BK
BL
G
G
GV
GV
Y
FLAME SENSE
FLAME SENSE
R
R
EXTERNAL POWER
EXTERNAL POWER
ACCESSORY INTERFACE
ACCESSORY INTERFACE
ACCESSORY INTERFACE
ACCESSORY INTERFACE
Part of J-BOX
Part of J-BOX
R
R
LWCO PROBE
LWCO PROBE
LWCO PROBE
LWCO PROBE
(317415-000 REV 1)
(317415-000 REV 1)
PUMP
PUMP
PUMP
PUMP
(EXTERNAL)
(EXTERNAL)
(EXTERNAL)
(EXTERNAL)
1 HP MAX
1 HP MAX
1 HP MAX
1 HP MAX
(SEE NOTE3)
(SEE NOTE3)
(SEE NOTE3)
(SEE NOTE3)
EXTERNAL POWER
EXTERNAL POWER
24VAC SWITCHED
24VAC SWITCHED
24VAC SWITCHED
24VAC SWITCHED
POWER
POWER
POWER
POWER
PROVER
PROVER
PROVER
PROVER
NO
NO
COM
COM
EXTERNAL ALARM
EXTERNAL ALARM
EXTERNAL ALARM
EXTERNAL ALARM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vb 2000Vw 1500Vw 2000

Table of Contents