Dell PowerEdge C5220 Hardware Owner's Manual page 107

Hide thumbs Also See for PowerEdge C5220:
Table of Contents

Advertisement

FTP Server Update
(Ex: ftp://user:user@192.168.1.111/s2gv112.bin)
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x30
0x03 0x01 0x10 0x03 0x00 0x00 0x00 0x01 0xFF 0x66 0x74 0x70 0x3A
0x2F 0x2F 0x75 0x73 0x65 0x72 0x3A 0x75 0x73 0x65 0x72 0x40 0x31
0x39 0x32 0x2E 0x31 0x36 0x38 0x2E 0x31 0x2E 0x31 0x31 0x31 0x2F
0x73 0x32 0x67 0x76 0x31 0x31 0x32 0x2E 0x62 0x69 0x6E
ASCII code for URL - " ftp://user:user@192.168.1.111/s2gv112.bin"
Response: 2a written data length
TFTP Server Update
(Ex: tftp://192.168.1.111/s2gv112.bin)
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x30
0x03 0x01 0x10 0x03 0x00 0x00 0x00 0x01 0xFF 0x74 0x66 0x74 0x70
0x3A 0x2F 0x2F 0x31 0x39 0x32 0x2E 0x31 0x36 0x38 0x2E 0x31 0x2E
0x31 0x31 0x31 0x2F 0x73 0x32 0x67 0x76 0x31 0x31 0x32 0x2E 0x62
0x69 0x6E
ASCII code for URL - "tftp://192.168.1.111/s2gv112.bin"
Response: 21 written data length
Updating BMC Firmware Through Firmware Command
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x08
0x01 0x01 0x80 0x00
Response: 34 firmware update task ID
(force update, config)
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x08
0x01 0x01 0x80 0x01
Response: 34 firmware update task ID
(normal update, no config)
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x08
0x01 0x01 0x00 0x00
Response: 34 firmware update task ID
(normal update, config)
Troubleshooting