P L E A S E R E A D A N D S AV E T H E S E
I M P O R TA N T S A F E T Y I N S T R U C T I O N S
When using electrical appliances, basic safety precautions should
17.NEVER use detergents, gasoline, glass cleaner, furniture polish, paint
always be followed to reduce the risk of fire, electric shock, and injury
thinner, or other household solvents to clean any part of the
humidifier.
to persons, including the following:
18.Excessive humidity in a room can cause water condensation on
1. Read all instructions before using the appliance.
windows and some furniture.
2. To avoid fire or shock hazard, plug the appliance directly into a
humidifier OFF.
120V AC electrical outlet.
19.Do not use humidifier in an area where humidity level is in excess
3. Keep the cord out of heavy traffic areas. To avoid fire hazard,
of 50%. Use a hygrometer, available at your local retailer or
NEVER put the cord under rugs or near heat registers.
through the manufacturer, to measure the humidity.
4. DO NOT place humidifier near heat sources such as stoves,
20.DO NOT attempt to repair or adjust any electrical or mechanical
radiators, and heaters. DO locate your humidifier on an inside
functions on this unit. Doing so will void your warranty. The
wall near an electrical outlet. The humidifier should be at least 4"
inside of the unit contains no user serviceable parts. All servicing
away from the wall for best results.
should be performed by qualified personnel only.
5. NEVER place humidifier in an area where it is accessible to children.
21.Never place housing under water flow or immerse in liquids.
NEVER use humidifier in a closed room, particularly where a child
22.Do not plug in the cord with wet hands: electric shock could result.
may be sleeping, resting, or playing (a closed room may result in
23.Do not pour water in any openings other than the water tank.
excessive humidity).
24.To prevent damage to surfaces, do not place humidifier under
6. WARNING: Do not attempt to refill humidifier without first
overhanging surfaces.
unplugging the unit from its electrical outlet. Failure to heed this
25.NEVER operate unit without water in the tank.
warning may cause personal injury. Be sure to unplug the unit by
26.Do not move unit after it has been used until unit cools completely.
pulling on the plug and not the cord.
27.Use both hands when carrying full tank of water.
7. Never place anything over moisture outlet when the unit is running.
8. NEVER drop or insert any object into any openings.
PLEASE READ AND SAVE
9. DO NOT operate any appliance with a damaged cord or plug, after
THESE IMPORTANT
the appliance malfunctions, or if it has been dropped or damaged
in any manner.
Return appliance to manufacturer for
SAFETY INSTRUCTIONS
examination, electrical or mechanical adjustment, or repair.
10.Use appliance only for intended household use as described in this
manual. Any other use not recommended by the manufacturer
Consumer Safety Information
may cause fire, electric shock, or injury to persons. The use of
Note: This is an electrical appliance and requires attention when in use.
attachments not recommended or sold by the manufacturer may
Note: If moisture forms on the walls or windows of the room, turn off the
cause hazards.
humidifier. The room already has plenty of humidity and additional
11.DO NOT use outdoors.
moisture may cause damage.
12.Always place humidifier on a firm, flat, level surface. A waterproof
Note: DO NOT block air inlet or outlet.
mat or pad is recommended for use under the humidifier. NEVER
Cord and Plug Installation Safety Instructions
place it on a rug or carpet, or on a finished floor that may be
damaged by exposure to water or moisture.
The length of cord used on this appliance was selected to reduce the
hazards of becoming tangled in, or tripping over a longer cord. If a
13.DO NOT allow the Moisture Outlet to directly face the wall. Moisture
longer cord is necessary an approved extension cord may be used. The
could cause damage, particularly to wall paper.
electrical rating of the extension cord must be equal to or greater than the
14.Humidifier should be unplugged when not in use.
rating of the humidifier. Care must be taken to arrange the extension
15.NEVER tilt, move, or attempt to empty unit while it is operating.
cord so that it will not drape over the countertop or tabletop where it can
Shut off and unplug before removing the water tank and moving
be pulled on by children or accidentally tripped over.
the unit.
16.This humidifier requires daily and weekly maintenance to operate
appropriately. Refer to daily and weekly cleaning procedures. Use
HOW COOL MIST WORKS
only cleaners and additives recommended by the manufacturer.
Your Holmes Cool Mist humidifier draws dry air through the rear air
intake grill area. This air is then passed through a moisture–laden wick
THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC
filter, which retains the minerals and deposits in the water. The resulting
(Alternating Current) PLUG (a plug having one blade wider
moist air is directed back into the room from the top air grill.
than the other). This plug will fit into the power outlet only
one way. If the plug does not fit fully into the outlet, reverse
NOTE: This humidification system provides a cool, invisible moisture
the plug. If it still does not fit, contact qualified personnel to
output. It is normal not to see the mist.
install the proper outlet.
NOTE: A humidity level below 20% can be unhealthy and uncomfortable.
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS
POLARIZED PLUG IN ANY WAY
The recommended humidity level is between 40%-50%.
F E AT U R E S - O P E R AT I O N S
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched to OFF and the unit is disconnected
from the electrical outlet.
2. Select a location for your humidifier, on a flat surface, about 4" away
If this happens, turn the
from the wall. DO NOT place the humidifier on a finished floor or
near furniture, which can be damaged by moisture or water. Place on
a moisture-resistant surface.

FILLING THE WATER TANK

1. Remove the tank from the base of the humidifier and bring to the
faucet. Turn the tank upside down and twist off the tank cap by
turning counter clockwise. Fill tank with cool, fresh tap water. DO NOT
fill with warm water as this may cause leaking. Replace the cap on
each tank FIRMLY.
2. When full, carry tank to the humidifier and place onto the base. The
tank holds 2.25 gallons of water and the base holds 1/4 gallons of
water. The tank will immediately begin to empty into base.
3. Plug the power cord into a 120V AC electrical outlet.
OPERATING INSTRUCTIONS
Your humidifier is equipped with a technologically advanced AccuSet Plus ™
digital Humidistat. You can set the humidifier to run continuously in manual
mode or set the AccuSet Plus™ digital Humidistat to your desired humidity
setting. The AccuSet Plus™ digital Humidistat will automatically turn the
humidifier ON or OFF, depending on the preset comfort level. The comfort
level ranges between 35% and 65% relative humidity.
Manual Mode Instructions:
1. Plug the humidifier into a 120V AC electrical outlet.
2. The display will show the current room humidity.
3. To start the unit, push the MODE/OFF button once for the HIGH (3)
manual setting.
4. Press the button again for the MEDIUM (2) manual setting and again
for LOW (1). After the selection is made, the display will return to
show the current room humidity.
5. To stop the unit, press and hold the button for two seconds, or keep
pressing the button until the display reads OFF.
AccuSet Plus™ HUMIDISTAT INSTRUCTIONS (see Fig. ?)
To take advantage of the AccuSet Plus™ Digital Humidistat, press the
MODE/OFF button until the speed is set in either the AUTO HIGH (A3),
AUTO MEDIUM (A2) or AUTO LOW (A1) setting. Then adjust the set
humidity by using the up and down buttons. Humidity will increase in
increments of 5%. When the humidity level is set, the display will return
to show the current room humidity. When the room humidity level rises
above the set humidity, the humidifier will stop. When the humidity level
drops below the set humidity, the humidifier will turn on automatically.
NOTE: Allow up to 30 minutes for the filter to fully absorb water and for
the unit to produce moisture.
NOTE: The AccuSet Plus™ Humidifier has memory. This means that
when you turn the unit back on, it will be at the last setting the humidifier
was set at.
If you do not plan to use the humidifier for two or more days, make sure
REPLACING THE FILTERS
any residual water is drained from the water tank, base and wick filter to
Through normal use, waterborne minerals and sediment become
prevent algae or bacteria growth.
trapped in the wick filter. The harder your water, the greater the
USING THE PROGRAMMABLE TIMER
amount of minerals in the
water, and the more often you
AccuSet Plus™ allows the user to program the humidifier to come on at a
will need to change your filter.
preset time, or turn off after a set amount of time.
You will be able to monitor the
Setting the Off Timer:
life of the filter in your
1. Set the mode and/or humidity you wish the humidifier to run in.
humidifier by checking the
2. While the humidifier is running, press and hold the up and down
FilterCheck
buttons simultaneously for 2 seconds. The display will flash "00".
unit is off, the FilterCheck
3. By pressing the up and down buttons, program the humidifier to turn
Indicator will read in the OFF position. After 60 minutes of use,
off up to 16 hours later in increments of 1 hour.
FilterCheck
4. After setting the timer, the display will return to show the current
your filter condition. A brand new filter will register in the blue
room humidity. The timer light will illuminate to show that the timer
section reading GOOD filter. After frequent use of your humidifier,
is activated.
the FilterCheck
5. After the predetermined length of time has passed, the humidifier will
be changed, see Figure ?.
automatically shut off.
When the needle is in the light blue (CHANGE) section, this means the
Setting the On Timer:
proper amount of moisture is not getting into your air due to the
1. While the humidifier is off, press and hold the up and down buttons
excessive minerals and sediment that have become trapped on your
simultaneously for 2 seconds.
filters. At this point, you should replace your filter. It is important to
change your filter as indicated to obtain stated performance level.
2. By pressing the up and down buttons, program the humidifier to turn
on up to 16 hours in advance in increments of 1 hour.
To replace the filter, follow the steps below: (see Fig. ?)
3. After the preset length of time has passed, the humidifier will
1. Turn the unit off and disconnect from the electrical outlet.
automatically turn on Auto Mode HI at 45% for a preset time of 2
2. Remove the tank and main housing to access the base tray.
hours.
3. Remove wick and discard.
AccuSet Plus™ REMOTE INSTRUCTIONS (For HM1865RC-U only)
4. Follow the weekly cleaning instructions.
1. Insert 2 AAA batteries into back of remote control.
5. Insert new filter.
6. Repeat Operating Instructions steps.
2. Press the Mode/Off button on remote to begin operation.
3. Use the remote to control the same features as the base unit.
It will take about 30 minutes for the humidifier to reach maximum
output.
NOTE: The timer function can only be activated on the base unit. It
cannot be activated via the remote control.
You can purchase replacement filters (Model HWF65) by calling 1-
NOTE: Do not mix new and old batteries. Do not mix alkaline, standard
800-5-HOLMES or by visiting www.holmesproducts.com. Please refer
(carbon-Zine), or rechargeable (nickel-cadmium) batteries.
to the Replacement Accessories section at the end of this manual for
the appropriate filter and solutions for this humidifier. It is
recommended that a replacement filter is purchased for
uninterrupted use.
CLEANING AND MAINTENANCE INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry, heated indoor
air. To benefit most from the humidifier and avoid product misuse,
follow all instructions carefully. Please note that this is an electrical
appliance and requires attention when in use.
In addition, if you do not follow the recommended care and
maintenance guidelines, micro-organisms may be able to grow in the
water within the water tank. You must routinely follow the cleaning
procedures that follow in order to ensure proper, efficient operation
of your humidifier. Proper maintenance and cleaning is essential to the
continued performance of your unit and the avoidance of algae or
bacteria build-up.
C L E A N I N G / M A I N T E N A N C E
R E P L A C I N G / S T O R A G E T H E F I LT E R
DAILY MAINTENANCE
1. Be sure the unit is OFF and is disconnected from the electrical outlet.
2. Remove the housing and the tank from the humidifier and place in
sink or tub.
3. Carry the base of the unit to the sink, remove the wick, place in sink,
Figure 1
drain any remaining water and rinse thoroughly to remove any
sediment or dirt. Wipe clean, and dry with a clean cloth or paper
towel.
4. Drain the water from the tank into the sink and rinse tank
®
Indicator. When the
thoroughly. Wipe clean, and dry with a clean cloth or paper towel.
®
5. Put filter back in, replace the housing, then refill tank with cool tap
water as instructed earlier in the Filling Instructions. DO NOT overfill.
®
Indicator will move from the OFF position and indicate
6. Follow Operating Instructions.
WEEKLY MAINTENANCE
®
Indicator will let you know when the filters need to
To Remove Scale:
1. Repeat steps 1-4 above.
2. Clean the base by partially filling the base with one 8-oz cups of
undiluted white vinegar, or by using CleanseClean
S1710) by the manufacturer. Leave this solution in the base for
20 minutes, while cleaning the all interior surfaces with a soft
brush. Remove base scale by wiping the base with a cloth
dampened with undiluted white vinegar.
3. Rinse with clean warm water to remove the cleaning solution
before disinfecting the tank.
To Disinfect Humidifier Base and Tank:
1. Fill humidifier base with 1/4 gallon of water and 1/2 teaspoon of
chlorine bleach.
2. Fill the tank 1/2 full with water and 1/2 teaspoon of chlorine bleach.
3. Let the solution stand for 20 minutes, swishing every few
minutes. Wet all surfaces.
4. Carefully empty the base and tank after 20 minutes, and rinse
with water until you cannot detect any bleach smell. Dry with a
clean cloth or paper towel.
5. Check the FilterCheck
filter. Depending on water hardness in your area, it may be
necessary to change the filter every 1-2 months. Reinsert the
wick filter into the base.
6. Refill the water tank as directed with cool tap water, replace the
humidifier housing, and turn the unit on.
STORAGE INSTRUCTIONS
When not using your humidifier for an extended period of time:
1. Dispose of the filters. DO NOT leave in unit.
2. Clean, rinse and thoroughly dry the humidifier as directed in
weekly maintenance. DO NOT leave any water in the unit when
storing. Leaving water in the unit may render the unit inoperable
for the following season.
3. Place the humidifier in the original carton and store in a cool, dry
place.
4. Order your replacement filter for next year's use.
®
(Model
®
Indicator to see if it is time to replace the

Hide quick links: