Download Print this page

Replacing The Filter; Storage Instructions - Holmes HM1850 Owner's Manual

Cool mist humidifier

Advertisement

C L E A N I N G I N S T R U C T I O N S - S T O R A G E

REPLACING THE FILTER

Through normal use, waterborne minerals and sediment become
trapped in the wick filter. The harder your water, the greater the
amount of minerals in the water, and the more often you will need
to change your filter.
You will be able to monitor the life of the filter in your humidifier by
checking the Filter Check™ Indicator. When the unit is off, the Filter
Check™ Indicator will read in the OFF position. After 60 minutes
of use, Filter Check™ Indicator (refer to figure 3 for close-up of
indicator) will move from the OFF
position and indicate your filter
condition. A brand new filter will
register in the blue section reading
GOOD filter. After frequent use of
your humidifier, the Filter Check™
Indicator will let you know when
the filter needs to be changed.
When the needle is in the red (CHANGE) section, this means the
proper amount of moisture is not getting into your air due to the
excessive minerals and sediment that have become trapped on your
filter. At this point, you should replace your filter. It is important
to change your filter as indicated to obtain stated performance level.
To replace the filter, follow the steps below.
1. Push the 1 Touch™ button (MODE/OFF) for 2 seconds to turn
the unit OFF and disconnect from the electrical outlet.
2. Remove the tank and main housing to access the base tray.
(See figures 1 and 2.)
3. Discard the old filter and follow weekly cleaning instructions.
4. Insert a new filter into the filter support in the base.
5. Replace the main housing and then the tank.
6. Repeat Operating Instruction steps.
It will take about 30 minutes for the humidifier to reach
maximum output.
You can purchase replacement filters (Model HWF65) by calling
1-800-5-HOLMES or by visiting www.holmesproducts.com. Please
refer to the Replacement Accessories section at the end of this
manual for the appropriate filter and solutions for this humidifier.
It is recommended that a replacement filter is purchased for
uninterrupted use.

STORAGE INSTRUCTIONS

If your humidifier will not be in use for two days or more,
or at the end of the season follow these instructions.
1. Clean and dry the humidifier thoroughly as per the Weekly
Maintenance instructions above.
2. Let the humidifier dry completely before storing.
Do not store with water inside the base.
3. Do not store with the reservoir cap in place.
4. Throw away the wicking filter. Do not store with wick filter in place.
5. Store in a cool dry location.
R E P L A C I N G T H E F I L T E R
Figure 3
CLEANING AND MAINTENANCE INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry indoor
air. To get the most of the benefit from the humidifier and
avoid product failure, follow all maintenance instructions
carefully. If the recommended care and maintenance
guidelines are not followed, micro-organisms may be
able to grow in the water within the humidifier.
DAILY MAINTENANCE
1. Before cleaning, push the 1 Touch™ button for 2 seconds
to turn the unit OFF and disconnect from the electrical outlet.
2. Lift off the tank and the housing of the humidifier.
3. Carry the base and the tank to the sink, remove the wick filter,
place in sink, then drain and rinse the base and tank thoroughly
to remove any sediment and dirt. Wipe clean and dry with a clean
soft cloth or paper towel. (DO NOT use metal cleaning utensils or
abrasive cleaners.)
4. Put the filter back in the filter supports, replace the housing, then
refill the tank with cool tap water as instructed in filling the water
tank instructions.
WEEKLY MAINTENANCE
Remove scale:
1. Repeat steps 1-3 above.
2. Clean the base by partially filling the base with one 8-oz
cup of undiluted white vinegar, or by using Cleanse Clean™
by Holmes. Let solution stand 20 minutes, clean all interior
surfaces with a soft brush.
3. Dampen a cloth with undiluted white vinegar and wipe out
entire base to remove scale.
4. Rinse with clean warm water to remove scale and the white
vinegar solution before beginning to disinfect the tank.
Disinfect Tank:
1. Fill tank with 1/2 teaspoon of chlorine bleach
and 1/2 gallon of water.
2. Let the solution stand for 20 minutes, swishing
every few minutes. Wet all surfaces.
3. Empty the tank after 20 minutes, and rinse well with water until
the bleach smell is gone. Dry with a clean cloth or paper towel.
4. Refill the water tank with cool water; replace the housing
and the water tank. Repeat ALL Operating Instructions.

Advertisement

loading