Download Print this page
LG ARNU243BGA2 Quick Manual
LG ARNU243BGA2 Quick Manual

LG ARNU243BGA2 Quick Manual

Multi v ducted (high static) 24,200 btu/h indoor unit
Hide thumbs Also See for ARNU243BGA2:

Advertisement

Quick Links

Job Name/Location:
Date:
PO No.:
Architect:
Engr:
Rep:
(Company)
ARNU243BGA2
Multi V™ Ducted (High Static)
24,200
Btu/h Indoor Unit
Performance:
Total Cooling  Capacity (Btu/h)
Heating Capacity (Btu/h) 
Power Input¹ (W)
Cooling Nominal Test Conditions:
Indoor:
80°F DB/67°F WB
Outdoor:
95°F DB
Electrical:
Power Supply (V/Hz/Ø)
Rated Amps (A)
Piping:
Refrigerant:
Liquid Line (in, OD)
Vapor Line (in, OD)
Condensate:
Condensate Line (in,OD)
Factory Installed Pump²
Controls Features:
•Auto changeover 
  (Heat Recovery only)
•Auto opera on
•Auto restart
•Child lock
•Dual thermistor control
•Group control
•E.S.P. control
Optional Accessories:
Wireless Handheld Remote Controller  (PQWRHDF0)
7‐Day Programmable Controller (PQRCUSA)
Simple Controller with Mode (PQRCUCS0C)
Simple Controller without Mode (PQRCFCS0C)
Dry Contact Unit (PQDSB1, PQDSBC)
Wall Mounted Temperature Sensor (PQRSTA0)
LG Electronics USA, Inc. 1000 Sylvan Ave, Englewood Cliffs, NJ 07632/www.lg‐vrf.com
For continual product development, LG reserves the right to change specifications without notice.
For:
File
Approval
GC:
Mech:
(Project Manager)
24,200
27,300
450
Heating Nominal Test Conditions:
Indoor:
70°F DB
Outdoor:
47°F DB/43°F WB
208‐230/60/1
2.3
3/8 Flare
5/8 Flare
1
Yes
•Hot start
•Self diagnos cs
•Sleep mode
•Timer (on/off)
•Weekly schedule
•So  dry (dehumidifica on)
•Fan speed control
³
Tag #:
Resubmit
Other
Entering Mixed Air:
Cooling Max⁴ (°F WB)
Heating Min (°F DB)
Unit Data:
Refrigerant Type
Refrigerant Control
Sound Pressure⁵ dB(A) (H/M/L)
Filter
Net Unit Weight (lbs)
Shipping Weight (lbs)
Fan:
Type
Quantity
Motor/Drive
Airflow Rate H/M/L (CFM)
External Static Pressure⁶ (in wg)
Standard Features:
•Limited Warranty with LG Cer fied Installa on
     •Two Year Functional Parts Warranty
Notes:
1.The Power Input is rated at high speed.
2.Maximum li  is 27 in from bo om of unit.
3.Requires a 7‐Day programmable controller.
4.See Engineering Manual for sensible and latent capaci es.
5.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
6.Factory set as standard.
7.All communica on cable to be minimum 18 AWG, 2‐conductor, stranded, shielded and must 
comply with applicable local and national code.
8.Power wiring cable size must comply with the applicable local and na onal code.
9.This unit comes with a dry nitrogen charge.
10.This data is rated 0   above sea level, with 25   of refrigerant line per indoor unit and a 0   
level difference between outdoor and indoor units.  All capacities are net with a combination ratio 
between 95 – 105%.
11.Must follow installa on instruc ons in the applicable LG installa on manual.
R410A
42/39/37
Washable Pre‐filter
Sirocco
Brushless Digitally Controlled/Direct
671/576/547
VRF‐SB‐DF‐015‐US   011H03
Page 1 of 2
76
59
EEV
84
95
1
0.39

Advertisement

loading

Summary of Contents for LG ARNU243BGA2

  • Page 1 3.Requires a 7‐Day programmable controller. •Dual thermistor control •So  dry (dehumidifica on) 4.See Engineering Manual for sensible and latent capaci es. •Group control •Fan speed control 5.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 6.Factory set as standard. •E.S.P. control 7.All communica on cable to be minimum 18 AWG, 2‐conductor, stranded, shielded and must  comply with applicable local and national code. Optional Accessories: 8.Power wiring cable size must comply with the applicable local and na onal code. 9.This unit comes with a dry nitrogen charge. ³ Wireless Handheld Remote Controller  (PQWRHDF0) 10.This data is rated 0   above sea level, with 25   of refrigerant line per indoor unit and a 0    level difference between outdoor and indoor units.  All capacities are net with a combination ratio  7‐Day Programmable Controller (PQRCUSA) between 95 – 105%. 11.Must follow installa on instruc ons in the applicable LG installa on manual. Simple Controller with Mode (PQRCUCS0C) Simple Controller without Mode (PQRCFCS0C) Dry Contact Unit (PQDSB1, PQDSBC) Wall Mounted Temperature Sensor (PQRSTA0) LG Electronics USA, Inc. 1000 Sylvan Ave, Englewood Cliffs, NJ 07632/www.lg‐vrf.com VRF‐SB‐DF‐015‐US   011H03 Page 1 of 2 For continual product development, LG reserves the right to change specifications without notice.
  • Page 2 Job Name/Location: ARNU243BGA2 Tag #: Multi V™ Ducted (High Static) Date: 24,200 Btu/h Indoor Unit PO No.: LG Electronics USA, Inc. 1000 Sylvan Ave, Englewood Cliffs, NJ 07632/www.lg‐vrf.com VRF‐SB‐DF‐015‐US   011H03 Page 2 of 2 For continual product development, LG reserves the right to change specifications without notice.