1-4. PICTURE TUBE REMOVAL

WARNING: BE ORE REMO ING THE ANODE CAP
High voltage remains in the CRT even after the power is disconnected. To avoid electric shock,
discharge CRT before attempting to remove the anode cap. hort between anode and CRT
coated earth ground strap.
WARNING
NOTE:
HOW TO HANDLE AN ANODE CAP

ANODE CAP REMOVAL PROCEDURE

before