EJU00530

Battery

If the watercraft is not used for a month or
more, disconnect the (–) battery cable first,
and then the (+) cable and breather pipe,
and next remove the battery from the craft.
Clean the battery casing using fresh
water.
If the battery terminals are dirty or cor-
roded, clean the mating surfaces on the ter-
minals for the battery cables using the wiring
brush or equivalents.
Recharge the battery, and then store it in
a cool and dark place.
Apply the Yamaha marine grease/Yamaha
grease A to the battery terminals.
Recharge the battery periodically at least
2 months because a battery will discharge
electricity by itself while storing.
CAUTION:
The battery may be impossible to use
again if you store it for a longer time
without recharging. Recharge the battery
periodically.
NOTE:
The battery condition can be found by
checking the specific gravity of the electro-
lyte. However, you can also know the battery
condition roughly by measuring the voltage
at both battery terminals. Recharge the bat-
tery if the voltage is 12 volts or less.
Specific gravity of electrolyte
(for reference):
1.28 at 20 °C (68 °F)
Yamaha recommend checking the specific
gravity of the electrolyte and charging bat-
tery by a Yamaha dealer or a battery dealer.
If you maintain the battery yourself, read
carefully the instructions for the tool and
machine before maintenance.
4-5