I M P O R T A N T S A F E G U A R D S
When using electrical appliances, basic safety precautions
14. DO NOT attempt to repair or adjust any electrical or
should always be followed to reduce the risk of fire,
mechanical functions on this unit. Doing so will void
electric shock, and injury to persons. These precautions
your warranty. The inside of the unit contains no user
include:
serviceable parts. All servicing should be performed
by Jarden Consumer Solutions or an authorized
1. Read all instructions before using the appliance.
Jarden Consumer Solutions Center.
2. To avoid fire or shock hazard, plug the appliance
15. DO NOT place anything on top of unit.
directly into a 120V AC electrical outlet.
16. NEVER use detergents, gasoline, glass purifier,
3. If the filter is covered by a bag when shipped,
furniture polish, paint thinner, or other household
remove plastic bag before use.
solvents to clean any part of the appliance.
4. Keep the cord out of heavy traffic areas. To avoid
17. Always turn the appliance off before unplugging it.
fire hazard, NEVER put the cord under rugs, near
heat registers, radiators, stoves, or heaters.
18. The ionizer in this appliance produces less ozone than
the UL established limits of 50ppb. However, in high
5. To protect against electrical hazards, DO NOT
concentrations, ozone can be harmful to birds and
immerse the appliance in water or other liquids. Do
small pets. To prevent ozone buildup, we suggest using
not use near water.
the ionizer in well ventilated areas with the fan on.
6. Close supervision is necessary when any appliance is
19. This appliance should only be used in a room with
used by or near children, or disabled persons.
temperatures between 40° F and 110° F.
7. Always unplug the air purifier before moving or
20. WARNING: To reduce the risk of fire or electric shock,
cleaning the unit, opening the grill, changing the filters
DO NOT use this appliance with any solid-state speed
and whenever the unit is not in use. To disconnect the
control device.
unit, be sure to pull the plug and not the cord.
8. NEVER drop or insert any objects into the openings of
PLEASE SAVE THESE
the unit.
IMPORTANT SAFETY
9. DO NOT operate any appliance with a damaged cord
or plug. If the motor fan fails to operate or the unit
INSTRUCTIONS
has been dropped or damaged in any manner, return
appliance to manufacturer for examination and/or
repair.
10. Use appliance only for intended household use
PLUG SAFETY
as described in this manual. Any other use not
CAUTION: To reduce the risk of
recommended by the manufacturer may cause
electric shock, THIS PRODUCT
fire, electric shock, or injury to persons. The use of
HAS A POLARIZED PLUG
attachments not recommended or sold by Jarden
(one blade is wider than the
Consumer Solutions may cause hazards.
other).
11. DO NOT use outdoors.
This plug will fit into a polarized
12. NEVER place on a soft surface such as a bed or sofa
outlet only one way. If the plug
as this could cause the unit to tip over and block the
does not fit fully into the outlet, reverse the plug. If it still
air inlet or outlet grills.
does not fit, contact qualified personnel to install the proper
13. Keep unit away from heated surfaces and open flames.
outlet. DO NOT ALTER THE PLUG IN ANY WAY.
F E A T U R E S
CORD SAFETY
charged particles such as dust, pollen, smoke, and pet
dander to form larger particles. These larger particles are
• The length of cord used on this appliance was
then more easily captured by the filter system.
selected to reduce tangling or tripping hazards.
Important Notes:
• If a longer cord is necessary, an approved extension
Your ionizer may produce an occasional popping or
cord may be used. The electrical rating of the
cracking sound. This is normal and occurs when a small
extension cord must be equal to or greater than the
buildup of ions is discharged.
electrical rating of the air purifier (see rating label
marked on product).
After extended use, you may notice dust around the grills
or front panel. This is caused by negative ions exiting
• Care must be taken to arrange the extension cord so
the air outlet, evidence of the ionizer's air cleaning
that it will not drape over the countertop or tabletop
effectiveness. You can remove the dust with a soft brush
where it can be pulled on by children or accidentally
or clean, damp cloth.
tripped over.
Larger particles may be attracted to positively charged
surfaces throughout the home, like walls or floors.
GET TO KNOW YOUR AIR PURIFIER
• This may occur more frequently when the filter is
• Your Sunbeam
air purifier features a HEPA-Type
®
nearing the end of its useful product life and unable
filter that removes up to 99% of airborne dust and
to capture as many charged particles.
pollen as small as 2 microns, and helps reduce
• Excessive amounts of pet dander, dust, or smoke
smoke, mold spores and pet dander from air passing
may decrease the life expectancy of the filter and
through the filter.
interfere with the ionization process.
• Arm & Hammer
®
baking soda and carbon help
To help prevent particles from attracting to surfaces
absorb and eliminate household odors.
throughout your home:
• Optional ionizer naturally improves performance and
• You may want to run the ionizer less often.
helps freshen the air.
• Check the condition of the filter more frequently.
CAUTION: The ionizer in this appliance produces less
IONIZER
ozone than the UL* established limits of 50ppb. However,
in high concentrations, ozone can be harmful to birds and
This appliance has an optional ionizer feature which,
small pets. The ionizer feature is not recommended for
when turned on, releases negative ions into outgoing
use in poorly ventilated areas where small animals
filtered air to help the air purification process.
are present.
What Are Ions?
Ions are tiny particles that carry a positive or negative
HEPA-TYPE FILTER
charge. They exist naturally around us: in the air, water,
and ground. Both positive and negative ions are colorless,
HEPA (High Efficiency Particulate Air) filters are
odorless, and harmless.
designed to remove up to 99% of airborne pollutants,
at 2 microns or larger, from the air that passes through
How Does The Ionizer Work?
them. These include tobacco smoke, household dust, pet
Negative ions help air purification by attaching themselves
dander and pollen.
to very small airborne particles in the room. These particles
take on a negative charge and may join with positively
*Tested and listed by the Underwriters Laboratories, Inc.
F E A T U R E S – O P E R A T I O N S
HIGH, MEDIUM AND LOW
Fig. 1
SPEED SETTINGS
For optimum air filtration, operate your Sunbeam
air
®
purifier continuously on the MEDIUM (
) setting. Its
rugged motor has been designed to give many years of
D
use. For quieter operation (such as in a bedroom), select
the LOW (
) setting. When high levels of air pollution
are present, select the HI (
) setting to quickly
circulate and filter the room air.
BEFORE USE
1. Carefully unpack your Air Purifier. Select a firm level
place where there are no obstructions to the air inlet
or filtered air outlet.
A. AIR INLET GRILL
2. If the filter is covered by a bag when shipped, remove
B. WASHABLE FOAM
plastic bag before use and place filters into unit.
PRE-FILTER
3. DO NOT POINT FILTERED AIR OUTLET TOWARDS WALL.
C. HEPA-TYPE/CARBON
FILTER
OPERATING INSTRUCTIONS
D. FILTERED AIR OUTLET
1. Plug into a 120V AC electrical outlet.
E. IONIZER LIGHT
2. Select the desired operating speed from HIGH (
),
F. IONIZER CONTROL
MEDIUM (
) or LOW (
) by moving the knob
G. SPEED CONTROL
to the desired setting.
3. To release negative ions into the filtered air, turn the
ionizer knob to ON (
) and the light will illuminate.
For optimum air filtration, it is recommended to operate
the air purifier continuously. Its rugged motor has been
designed to give many years of use.
C L E A N I N G / M A I N T E N A N C E
F I L T E R R E P L A C E M E N T
CLEANING/MAINTENANCE INSTRUCTIONS
To replace your filter:
1. Turn off and unplug the air purifier.
1. Turn the air purifier off and unplug it before cleaning.
2. Open the air inlet grill and examine the foam
2. The outside of the air purifier can be cleaned with a
prefilter. Remove any dust or lint, and wash in warm
soft, clean dampened cloth.
A
soapy water. Rinse, drip dry, and place back into grill
3. The rear air inlet grill can be removed and washed in
inlet.
warm soapy water (not dishwasher safe). Dry before
3. Remove used filter from the unit by pulling it gently
replacing in the unit.
B
towards you and discard it. DO NOT attempt to clean
4. The filtered air outlet can be cleaned of dust with a
the old HEPA-type filter.
small, soft brush.
4. Install the new HAPF30 HEPA-type filter into the
5. If you wish to clean the inside of the air purifier,
unit. This model utilizes a hang tab and filter clips
please only use a dry, soft cloth to wipe it down.
to insure that the filter is properly in place. Before
WARNING: Do not allow moisture to come in contact
replacing the filter,
with the main housing of the air purifier.
make sure that the hang
C
tab is securely in place.
The clip can only be
FILTER REPLACEMENT INSTRUCTIONS
E
attached to the tabs on
IMPORTANT:
the filter one way. The
filter clip should easily
F
• DO NOT attempt to wash and re-use the HEPA-type
slide onto the filter hang
filter.
tab with only a small
NOTE:
amount of pressure.
G
DO NOT use force while
Every few weeks, check the condition of filters. Filter life
attaching the clip to the
will vary, depending on air quality and usage. Under
filter. (Fig. 2)
normal conditions of continuous use, the HEPA-type filter
will operate efficiently for 3-6 months.
5. Align the clip on the side
of HEPA-type filter with
rails on the inside of the
purifier unit. Gently slide the filter onto the rail. (Fig. 3)
6. Replace air inlet grill.
Air Purifier
Filter Quantity
Filter Model
Model Number
Needed
Number
HAP412
1
HAPF30 A Filter
Fig. 2
Fig. 3
Filter
Description
HEPA-type Filter

Advertisement