• Optional use tamper-resistant feature serves as a safeguard against
tampering.
• Unique "battery missing" device. The heat alarm will not attach to
the mounting bracket if a battery is not in the battery compartment.
• The heat alarm will sound a short beep about once a minute if the
battery is low or improperly connected.
• Multi-purpose green and red LEDs indicate that the heat alarm is con-
nected to the AC supply, is working normally, or is in alarm.
• Loud alarm sounder – 85 decibels [dB(A)] at 3m – will sound to alert
you of an emergency.
• Test button checks heat alarm operation.

SPECIFICATIONS

M
N
ODEL
UMBER
E
R
LECTRICAL
ATING
I
NTERCONNECTING
S
H
MOKE AND
EAT
(
P
OR
ATTRESS WITH
T
R
EMPERATURE
ATING
M
A
AXIMUM
MBIENT
T
U
EMPERATURE AT
O
T
PERATING
EMPERATURE
R
C
ECOMMENDED
R
S
ECOMMENDED
M
D
AXIMUM
ISTANCE FROM
M
C
AXIMUM
EILING

IMPORTANT SAFETY INFORMATION

PLEASE READ AND SAVE THESE INSTRUCTIONS
!WARNING
• This heat alarm requires constant 230V AC power AND a healthy
9V DC battery to operate properly. This heat alarm WILL NOT work if
AC power is not connected, or has failed or been interrupted for any
reason, AND the batteries have been removed or are flat or improp-
erly connected. DO NOT use any other kind of battery except as
specified in this manual. DO NOT interconnect this heat alarm to
any other type of smoke alarm or heat alarm or auxiliary device,
except those listed in this manual.
• The Push-to-Test button accurately tests all heat alarm functions.
DO NOT use any other test method for routine testing. Test heat
alarm weekly to ensure proper operation.
• Higher ceilings will increase the time needed by the heat alarm to
detect a fire. In most dwellings the ceiling height will keep this reac-
tion time within acceptable limits. However, ceilings with a height of
over 6m may delay the reaction time of the heat alarm significantly.
F
IREX
A
LARMS
R
)
ELAY
NIT
OVERAGE
PACING
W
ALL
H
EIGHT
H230
230V AC, 9 V
OLT
U
P TO ANY COMBINATION OF
A
(M
H230)
LARMS
ODEL
(M
GC240, I240C, IAR230C, PG240,
ODELS
PAD240, PADC240
N
: T
OTE
HE ABOVE
INTERCONNECTED WITH
PATR). H
(M
ODEL
12
TION OF
OF THESE MODELS
H
A
EAT
LARMS AND
INTERCONNECTED AT ONE TIME
57°C F
IXED TEMPERATURE
37.8°C
-23°C
70°C
TO
2
50
M
5.3
M
7.7
M
6
M
2
DC
BATTERY BACKUP
35
OTHER
F
S
OR
IREX
PAR230)
AND
F
IREX MODELS MAY BE
F
P
IREX
ATTRESS WITH
,
OWEVER
A MAXIMUM COMBINA
(F
IREX
P
R
ATTRESS WITH
ELAY
.
F
H
IREX
EAT
A
MOKE
LARMS
R
ELAY
-
S
MOKE AND
)
MAY BE

Advertisement

Table of Contents
loading

Table of Contents