4-1. TROUBLESHOOTING GUIDE
PROBLEM
Product not
holding
temperature
Refrigeration unit runs
constantly
Power switch on but
no power to unit
Not all lights
on
Lights will
not turn on
4-1
SECTION 4. TROUBLESHOOTING
CAUSE
• Cold well or hot well not
plugged-in
• Product held too long
• Cold well setting turned
• Compressor overheated
• Product not a proper
temperature when placed
into unit
• Defective fuse for refrigeration
unit
• Frost build-up
• Condensor coil dirty
• Open Circuit
• Faulty light bulbs
• Defective fuse
Model HDS-200/300
CORRECTION
• Check plugs under table-top
on french fry end of HDS-300
• Only hold product for
recommended times
• Turn control setting to about 6
• Clean condenser coil
• Be sure product is at proper
temperature
• Replace 15 amp fuse
• Defrost unit
• Clean condenser coil
• Plug unit in
• Check circuit breaker
• Check 15 amp fuses
• Check cord and plug
for loose connection
• Replace with new bulb,
per Light Bulb Replacement
Section
• Replace 15 amp fuse
605