INSTRUCTION MANUAL FISH FINDER MXF-5000 This device complies with Part 15 of the FCC Rules. Opera- tion is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
If disregarded, inconvenience only. No risk NOTE of personal injury, fi re or electric shock. Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the United Kingdom, Germany, France, Spain, Russia and/or other countries.
KEEP the fi sh fi nder out of the reach of children. OFF, and remove the power cable if it emits an abnormal odor, sound or smoke. Contact your Icom KEEP the fish finder away from heavy rain, and dealer or distributor for advice.
GROUND TERMINALS (p. 3) Connect these terminals to ground to prevent electrical shocks. e MarineCommander™ CONNECTOR (p. 3) Connect this connector to the Icom MarineCom- mander™. r TRANSDUCER1/2 CONNECTORS (pgs. 3–6, 8) Connect the transducer to either connector. NEVER CONNECT 2 transducers to these...
INSTALLATION AND CONNECTIONS For qualifi ed equipment installers ONLY ■ Jumper setting (When connecting an EX-3195 ONLY) DO NOT open the bottom cover of the fish finder unless connecting an EX-3195. When connecting an EX-3195, move the jumper (MAIN unit; J15) to the 1 kW position as follows. CAUTION: Before changing the jumper setting, make sure disconnecting the fi...
EX-3194 EX-3195 EX-3193 NEVER connect anything 600 W Tramsom type, 600 W Thru Hull type, 1 kW Thru Hull type, other than Icom optional built-in boat speed and built-in boat speed and built-in temperature transducers. temperature sensors) temperature sensors) sensor) Optional transducers Detach the terminal guard first.
INSTALLATION AND CONNECTIONS ■ Mounting First, drill four φ5.5–6 mm ( ″) holes to mount ⁄ – ⁄ the fi sh fi nder using the units base as a pattern. Mount the fish finder securely with the four supplied bolts (M5×30 mm) to a flat surface which supports more than approx.
Page 9
INSTALLATION AND CONNECTIONS D Installation position The performance of the fish finder greatly RDANGER: A transducer MUST BE installed by a depends on the installation position of the trans- shipbuilder or a qualifi ed installer. ducer. See transducer’s instruction manual for Improper installation could cause water leaks and details.
Page 10
INSTALLATION AND CONNECTIONS D Optional transducer’s dimensions (approx.) • EX-3193 (600 W Transom type, built-in boat speed and temperature sensors) 155 mm (6.12″) 70 mm (2.76″) • EX-3194 (600 W Thru Hull type, built-in boat speed and temperature sensors) 2-12″ 142 mm threads (5.59″)
Icom is not responsible for the destruction or Proper maintenance allows to the system to be kept damage to an Icom fish finder in the event the in a optimum state and reduces the possibility of mal- Icom fish finder is used with equipment that is not functions.
SPECIFICATIONS ■ MXF-5000 • Power supply : 10.8 V to 31.2 V DC • Current drain : Less than 0.6 A (water depth range: 40 m/output power: 600 W at 12 V DC) Less than 1.0 A (water depth range: 40 m/output power: 1 kW at 12 V DC) •...