Free-standing epa certified wood-burning stoves country collection (22 pages)
Summary of Contents for Lennox Hearth Products STRIKER S160
Page 1
INSTALLATION AND OPERATION MANUAL Free-Standing EPA Certified Wood-Burning Stoves Save These Instructions For Future Reference P/N 775214M, Rev. F, 09/2011 Striker™ S160 SWS160 Wood Stoves Models Striker™ S160 and SWS160 A French manual is available upon request. Order P/N 775214CF. Ce manuel d’installation est disponible en francais, simplement en faire la demande.
Stove Installation ................. 12 Pedestal Installation ..............13 Thank you for selecting a Lennox Hearth Products wood stove as the answer to your home supplemental heating needs. Post Installation Checks ............... 14 Brick Installation ..............14-15...
ing season to check for soot and creosote accumulations. IMPORTANT SAFETY AND WARNIING Any accumulations over 1/8” thick should be removed by INFORMATION a professional chimney sweep. Do not attempt to burn out heavy creosote accumulations with a hot fire. If large ac- cumulations are occurring, review your burning procedures.
read greater than .04’ W.C. (inches water column) and less than .08” TESTING INFORMATION W.C. As per NFPA-211 standard (see paragraph below), the installer must take into account all variables within the installation and install the appliance in such a manner that satisfies the draft requirements of the This manual describes the installation and operation of these non-catalytic appliance.
(cat. no. H8159), available from all you need to clean to be safe. Be aware that the hotter the fire the Lennox Hearth Products dealers. less creosote is deposited, and weekly cleaning may be necessary...
Chimney and Connector CLEARANCES TO COMBUSTIBLES Minimum 6” diameter, minimum 24 MSG black steel connector pipe with UL103HT listed factory-built chimney suitable for use with solid fuels WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN THE or masonry chimney. Horizontal connection not tested, refer to local HEATER AND THE SURFACE OF ANY COMBUSTIBLE CONSTRUC- building codes for installation.
INSTALLATION CLEARANCES - REFER TO FIGURES 2, 3 ANd 4 PIPE INSTALLATION B (1) D (1) E† F (1,4) G (4) 6” Single Wall Residential or USA-16” 14” USA-21” 12-1/2” 8” 9-3/4” USA-18” Alcove CAN-483mm 356mm CAN-610mm 318mm 200mm 248mm CAN-533mm Residential or USA-10” 8”...
Single Wall Pipe STAINLESS STEEL LINER Using 6” Diameter Single Wall Connector Pipe Using 6” Diameter Rigid Stainless Steel Liner INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTRUCTIONS! INSTRUCTIONS! Chimney Chimney Termination Termination Rain Cap Shown with Tubinox™ Stainless Steel Liner components (see Page 28 for ordering information)
CHIMNEY INSTALLATION Double Wall Pipe • Install chimney as per manufacturer’s instructions. Some brands of Using 6” Diameter Type L-Vent Connector Pipe pipe may require removal of the spacer ring in the flue collar. Mobile (Manufactured) Home Installation Shown • All horizontal runs of pipe should be as short as possible and are INSTALL VENTING SYSTEM PER VENT MANUFACTURERS required by NFPA No.
Chimney Connector Systems and Clearances from Combustible System A Walls for Residential Heating Appliances (NFPA 211) Refer to Minimum chimney clearance to brick Figure 8 and combustibles 2 in. (51mm) System A. Minimum 3.5 in. (90 mm) thick brick masonry wall Minimum clearance 12 in.
Open all cartons, if any and remove the contents upon receipt and check for any damaged or missing parts. If there is hidden damage, notify your BACK freight company or Lennox Hearth Products dealer immediately. Heat Shield CAUTION: Wear gloves during installation in case of sharp Mounting Holes edges on the stove.
14. All horizontal runs of pipe should be as short as possible and are STOVE INSTALLATION required by NFPA No. 211 to have an upward pitch or rise in the same direction the smoke travels of no less than 1/4” to the linear foot. The connector pipe must meet minimum clearances in any direction If not previously installed, install floor protection and move the to walls or other combustible materials.
If required, install the Outside Air Kit (cat. no. 71112) as per the PEDESTAL INSTALLATION following instructions. To locate the hole in the hearth for outside air mark and cut a 4” (102 mm) hole in the hearth. The hole’s center should be 3”...
BRICK INSTALLATION POST INSTALLATION CHECKS Check that all chimney pipe joints are securely fastened. CAUTION: Wear gloves during brick installation in case of sharp edges inside the stove. Check that the heater is securely fastened to the floor (if ap- plicable).
Page 15
3. Next, you will install the baffle blanket. It will be installed with the 4. The final step of the baffle board & baffle blanket installation will be installing the front baffle boards. The front baffle boards will be the 11”...
OPERATING HINTS STARTING AND MAINTAINING A FIRE 1. Burn only dry, well-seasoned wood for maximum heat output. In some Be sure to clean plated accessories with a household type states it is illegal to burn wet wood or anything other than clean, dry cleaner and a very soft cloth to remove any fingerprints and wood products.
BLOWER OPERATION Blower Operation The blower can be operated manually or automatically (blower will turn on when the stove is hot and turn off when the stove is cool). The rocker switch on the control panel allows you to select between manual operation or automatic operation as follows (see Figure 19): MANUAL OPERATION: Turn rocker switch to the “MANU- AL”...
All Lennox Hearth Products stoves are EPA tested for emissions at low insert will enhance its overall efficiency and performance. What this can burn with the air control completely closed.
DOOR HINGES: If door hinges need lubricating, use an anti-seize com- to cleaning glass. A commercial glass cleaner pound (never use oil) available from your Lennox Hearth Products dealer. designed for stoves is recommended. Do not use DOOR LATCH: If your door latch fails to latch tightly and the gasket is abrasive cleaners.
TROUBLESHOOTING Problem Solution POOR DRAFT: Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor drafts. Remember, the stoves’ draft depend solely on the natural draft of the chimney (See Draft Requirements on Page 4).
Check the chimney and baffle monthly to make sure they are clean. Burn seasoned, dry wood only! (RAIN = WET WOOD) Open the door frequently during Burn-In Period to keep gasket from adhering to the curing paint. Enjoy the warm feeling of your new Lennox Hearth Products appliance.
Page 22
Aluminum Flex Tubing Kit w/ clamp (15” of 4” dia.) H5558 Single Black Cascade Leg Contact an Lennox Hearth Products dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts H5669 Single Black Olympic Leg can result in poor performance and safety hazards.
Page 23
REPLACEMENT PARTS - MODELS S160 AND SWS160 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 24
REPLACEMENT PARTS - MODELS S160 AND SWS160 Door Parts Blower Parts NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 25
REPLACEMENT PARTS - MODELS S160 AND SWS160 Leg and Leg Parts NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 26
REPLACEMENT PARTS - MODELS S160 AND SWS160 Ash Drawer Pedestal and Pedestal NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
ACCESSORIES - MODELS S160 AND SWS160 Cat. No. Model Description Pc. / Container Supports (continued) TEE SUPPORT Secure Temp® Factory-Built Chimney 6” Secure Temp ASHT and Secure Temp G-ASHT 6SMA 6SMA GALVALUME ADJUSTABLE TEE SUPPORT (2” TO 6”) Cat. No. Model Description Pc.
The Date On Which Your Appliance Was Installed __________________________ Your Dealer's Name _________________________________________________ Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.