Termination; Linking - American DJ MB DMX User Instructions

2-channel dmx mirrorball motor
Table of Contents

Advertisement

REMOTE
INPUT
OUTPUT
SOUND
CONTROL
INPUT
MB DMX™
Notice:
Be sure to follow figure three when making your own cables.
Do not use the ground lug on the XLR connector. Do not connect the
cable's shield conductor to the ground lug or allow the shield conduc-
tor to come in contact with the XLR's outer casing. Grounding the
shield could cause a short circuit and erratic behavior.
DMX512
XLR Male Socket
XLR Female Socket
DMX+,DMX-,COMMON
1 Ground
2 Cold
2 Cold
REMOTE
INPUT
OUTPUT
CONTROL
INPUT
3 Hot
Figure 2
1
DMX512 OUT
3
3-PIN XLR
2
POWER
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number ZDMX/T) will decrease the possibilities of erratic
behavior.
Termination reduces signal errors and
avoids signal transmission problems
1
1
DMX512 IN
3
3
and interference. It is always advisable
3-PIN XLR
to connect a DMX terminal, (Resistance
2
2
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
5-Pin XLR DMX Connectors:
connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures
may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be
used, these adaptors are readily available at most electric stores. The
chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor
3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
©American DJ® - www.americandj.com - MB DMX™ Instruction Manual Page 7
REMOTE
SOUND
CONTROL
INPUT
POWER
XLR Pin Configuration
1 Ground
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
REMOTE
INPUT
OUTPUT
SOUND
CONTROL
INPUT
3 Hot
Pin 3 = Data True (positive)
COMMON
DMX +
1
DMX512 IN
3
3-PIN XLR
DMX -
2
Figure 3
When longer runs of cable are
Figure 4
Some manufactures use 5-pin XLR
5-Pin XLR Male (In)
Pin 1
Pin 1
Pin 2
Pin 2
Pin 3
Pin 3
Do Not Use
Do Not Use
INPUT
OUTPUT
SOUND
Set Up
MB DMX™
Master/Slave Linking:
For a more dramatic effect, link several MB DMX™ together. Your
fixture comes with built-in programs. These programs are designed
to work with up to 4 units when daisy-chained together in a master-
POWER
slave configuration. Any unit can function as either a "Master Unit" or
a "Slave Unit." Link the units together using standard DMX cable as
described on pages 6 and 7.
Optional MINI/C blackout controller
Termination reduces signal errors and
avoids signal transmission problems
1
and interference. It is always advisable
3
2
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
POWER
Optional MINI/C:
The optional MINI/C controller
allows all units linked together
to blackout. This unit will only
blackout the fixtures and will not
change or select different pro-
grams.
30 Foot Extension Cable
REMOTE
INPUT
OUTPUT
CONTROL
INPUT
POWER
DMX IN
DMX OUT
Blackout Indicator
Blackout Button
©American DJ® - www.americandj.com - MB DMX™ Instruction Manual Page 8

Linking

DMX IN
DMX OUT
To next MB DMX™ if applicable

Advertisement

Table of Contents
loading

Table of Contents