Download Print this page

Progress Replacement Motion Sensor P6036 Owner's Manual

Replacement motion sensor

Advertisement

Quick Links

Replacement
Motion Sensor
Model P6036
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight
hours.
• LED indicates motion was sensed (day or night).
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must
be wired through a switch.
• Some codes require installation by a qualified
electrician.
OPERATION
Mode:
On-Time
Test
5 Seconds
Auto
1, 5, or 10 Min
Manual
To Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
for the circuitry to calibrate.
Works: Day Night
x
x
x
x
/
minutes
1
2
Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.
Put the ON-TIME switch in the 1,
5, or 10 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one
second then back on to toggle
between AUTO and MANUAL
MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn
the power off for one minute, then back on. After
the calibration time the control will be in the AUTO
mode.
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
1 Second
OFF then...
... back on.
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch
off for one second
then back on*
598-1280-00

Advertisement

loading

Summary of Contents for Progress Replacement Motion Sensor P6036

  • Page 1 Replacement Motion Sensor Model P6036 Features • Turns on lighting when motion is detected. • Automatically turns lighting off. • Photocell keeps the lighting off during daylight hours. • LED indicates motion was sensed (day or night). Requirements • The Light Control requires 120-volts AC. • If you want to use Manual Mode, the control must be wired through a switch. • Some codes require installation by a qualified electrician. OPERATION Mode: On-Time Test 5 Seconds Auto 1, 5, or 10 Min Manual To Dawn* * resets to Auto Mode at dawn. Note: When first turned on wait about 1 for the circuitry to calibrate.
  • Page 2 INSTALLATION For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of elec- trical shock. For eave mount only: ❒ Swing the sensor head towards the clamp screw. Clamp Screw ❒ Rotate the sensor head clockwise 180° so the controls face down. Controls If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done. These instructions show the sensor wired to flood- lamps. T he white sensor wire is neutral. T he black sensor wire is hot. The red wire is the switched "hot" wire. The lighting load (500 W, 4.A max) is placed across the white and red wires.
  • Page 3: Test And Adjustment

    TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 period before it will detect motion. When first turned on, wait 1 ❒ Turn the RANGE control to the mid position and the ON-TIME control to the TEST position. ON-TIME 10 5 1 TEST Bottom of Sensor...
  • Page 4: Troubleshooting Guide

    TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE Lights will not 1. Light switch is turned off. come on. 2. Light is loose or burned out. 3. Fuse is blown or circuit breaker is turned off. . Daylight turn-off is in effect (recheck after dark). 5. Incorrect circuit wiring, if this is a new installation. 6. Re-aim the sensor to cover desired area. Lights come on 1. Light Control may be installed in a in daylight.