Summary of Contents for Sunix ESW-5242GP

  • Page 1 SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw USER’S MANUAL Management Ethernet Switch ESW-5242GP / ESW-5162GP Ver. 1.0, Apr. 2007...
  • Page 2: Table Of Contents

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Table of Content 1. Getting to Know Your Switch ......................................4 About the ESW-5242GP / ESW-5162GP Switch..........................4 Software Features......................................4 Hardware Features ......................................4 2. Hardware Overview ..........................................5 Front Panel..........................................5 Rare Panel ...........................................5 Rack mount kit assembly ...................................6 3.
  • Page 3 SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw 5.3.7 IGMP C ..................................49 OMMANDS 5.3.8 MAC / F ............................50 ILTER ABLE OMMANDS 5.3.9 SNMP C ..................................50 OMMANDS 5.3.10 ............................51 IRRORING OMMANDS 5.3.11 802.1 ................................51 OMMANDS 5.3.12...
  • Page 4: Getting To Know Your Switch

    About the ESW-5242GP / ESW-5162GP Switch The ESW-5242GP / ESW-5162GP switches are powerful managed switches which have many features. These switches can be managed by WEB, TELNET, Consol or other third-party SNMP software as well. Besides, these switches can be managed by a useful utility that we called Super-VIEW.
  • Page 5: Hardware Overview

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw 2. Hardware Overview 2.1 Front Panel The following table describes the labels that stick on the ESW-5242GP / ESW-5162GP. Port Description 10/100 RJ-45 fast 24/16 10/100Base-T(X) RJ-45 fast Ethernet ports support Ethernet ports auto-negotiation.
  • Page 6: Rack Mount Kit Assembly

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw 2.3 Rack mount kit assembly You can find the rack mount kit and the screws in the packing box. Please assembly the rack mount kit on the switch with screws as below picture.
  • Page 7: Cables

    3.1 Ethernet Cables The ESW-5242GP / ESW-5162GP switches have standard Ethernet ports. According to the link type, the switches use CAT 3, 4, 5,5e UTP cables to connect to any other network device (PCs, servers, switches, routers, or hubs). Please refer to the following table for cable specifications.
  • Page 8: Console Cable

    Switch A. Fiber cord Switch B. 3.3 Console Cable ESW-5242GP / ESW-5162GP switches can be management by console port. You can connect them to PC through a RS-232 cable PC pin out (male) assignment DB9 female connector on switch Pin #2 RD...
  • Page 9: Web Management

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw 4. WEB Management 4.1 Configuration by Web Browser This section introduces the configuration by Web browser. 4.1.1 BOUT BASED ANAGEMENT Inside the CPU board of the switch, an embedded HTML web site resides in flash memory.
  • Page 10: Main Interface

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw 4.1.4 NTERFACE Main interface 4.1.5 YSTEM NFORMATION Assigning the system name, location and view the system information System Name: Assign the name of switch. The maximum length is 64 bytes System Description: Display the description of switch. Read only cannot be modified System Location: Assign the switch physical location.
  • Page 11: Dhcp Server Ystem Configuration

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw IP configuration interface 4.1.7 DHCP S – S ERVER YSTEM CONFIGURATION The system provides the DHCP server function. Enable the DHCP server function, the switch system will be a DHCP server.
  • Page 12: Dhcp Server Ort And Ip Bindings

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw DHCP Client Entries interface 4.1.9 DHCP S IP B ERVER ORT AND INDINGS You can assign the specific IP address that is the IP in dynamic IP assign range to the specific port. When the device is connecting to the port and asking for assigning dynamic IP, the system will assign the IP address which has been assigned before to the connected device.
  • Page 13: Tftp - Restore Configuration

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Click Apply Update Firmware interface 4.1.11 TFTP – R ESTORE ONFIGURATION You can restore EEPROM value from TFTP server, but you must put back image in TFTP server, switch will download back flash image.
  • Page 14: System Event Log - Smtp Configuration

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw After configuring, Click Apply Syslog Configuration interface 4.1.14 S - SMTP C YSTEM VENT ONFIGURATION You can set up the mail server IP, mail account, account password, and forwarded email account for receiving the event alert.
  • Page 15: System Event Log - Event Configuration

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw SMTP Configuration interface 4.1.15 S YSTEM VENT VENT ONFIGURATION You can select the system log events and SMTP events. When selected events occur, the system will send out the log information.
  • Page 16: Sntp Configuration

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Event Configuration interface 4.1.16 SNTP C ONFIGURATION You can configure the SNTP (Simple Network Time Protocol) settings. The SNTP allows you to synchronize switch clocks in the Internet. SNTP Client: enable or disable SNTP function to get the time from the SNTP server.
  • Page 17 SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Oscar Time Zone -2 hours 10 am ADT - Atlantic -3 hours 9 am Daylight AST - Atlantic Standard -4 hours 8 am EDT - Eastern Daylight EST - Eastern Standard...
  • Page 18: Ip Security

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw USSR Zone 9 IDLE - International Date Line NZST - New Zealand +12 hours Midnight Standard NZT - New Zealand SNTP Sever URL: set the SNTP server IP address. Daylight Saving Period: set up the Daylight Saving beginning time and Daylight Saving ending time. Both will be different in every year.
  • Page 19: User Authentication

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw IP Security interface 4.1.18 U UTHENTICATION Change login username and password for the web management security. Username: Key in the new username(The default is “admin”) Password: Key in the new password(The default is “admin”)
  • Page 20: Advanced Configuration - Aging Time

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw 4.1.20 A – A DVANCED CONFIGURATION GING Aging Time of MAC Table: Default 300secs. Auto Flush MAC Table When Link Down: enable/disable the function 4.1.21 A – J DVANCED CONFIGURATION UMBO FRAME Jumbo Frame: Enable/disable per port Jumbo frame function.
  • Page 21: Port Control

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Port Statistics interface 4.1.23 P ONTROL In Port control, you can view every port status which depend on users’ setting and the negotiation result. Port: select the port that you want to configure.
  • Page 22: Port Trunk

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Port Control interface 4.1.24 P RUNK The Link Aggregation Control Protocol (LACP) provides a standardized means for exchanging information between Partner Systems on a link to allow their Link Aggregation Control instances to reach agreement on the identity of the Link Aggregation Group to which the link belongs, move the link to that Link Aggregation Group, and enable its transmission and reception functions in an orderly manner.
  • Page 23: Aggregator Information

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Port Trunk—Aggregator Setting interface 4.1.24.2 Aggregator Information When you had setup the LACP aggregator, you will see relation information in here. Port Trunk – Aggregator Information interface 4.1.24.3 State Activity After you setup the LACP aggregator, you can configure port state activity. You can mark or un-mark the port. When you mark the port and click button the port state activity will change to Active.
  • Page 24: Port Mirroring

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Port Trunk – State Activity interface 4.1.25 P IRRORING The Port mirroring is a method for monitor traffic in switched networks. Traffic through ports can be monitored by one specific port. That means traffic goes in or out monitored (source) ports will be duplicated into mirror (destination) port.
  • Page 25: Vlan Configuration

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Rate Limiting interface All the ports support packet ingress and egress rate control. For example, assume port 1 is 10Mbps, users can set the rate of effective egress to 2Mbps, and ingress rate to 1Mbps. The switch performs the ingress rate by packet counter to meet the specified rate InRate: Enter the port effective ingress rate(The default value is “0”)
  • Page 26: Vlan Configuration - Port-Based Vlan

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw VLAN Configuration interface 4.1.27.1 VLAN configuration - Port-based VLAN Packets can go among only members of the same VLAN group. Note all unselected ports are treated as belonging to another single VLAN. If the port-based VLAN enabled, the VLAN-tagging is ignored.
  • Page 27: 802.1Q Vlan

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw VLAN—Port Based Add interface You will see the VLAN displays. button to delete unwanted VLAN. Delete button to modify existing VLAN group. Edit [NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will lose when switch power off.
  • Page 28 SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw 802.1q VLAN interface Group Configuration Edit the existing VLAN Group. Select the VLAN group in the table list. Click Edit Group Configuration interface You can Change the VLAN group name and VLAN ID.
  • Page 29: Apid Panning Ree

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Group Configuration interface 4.1.28 R APID PANNING The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change. The system also supports STP and the system will auto detect the connected device that is running STP or RSTP protocol.
  • Page 30: Rstp - Port Configuration

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw RSTP System Configuration interface 4.1.28.2 RSTP - Port Configuration You can configure path cost and priority of every port. Select the port in Port column. Path Cost: The cost of the path to the other bridge from this transmitting bridge at the specified port. Enter a number 1 through 200000000.
  • Page 31: Snmp Configuration

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw RSTP Port Configuration interface Admin Edge: The port is directly connected to end stations and it cannot create bridging loop in the network. To configure the port as an edge port, set the port to “True” status.
  • Page 32: Trap Configuration

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Click To remove the community string, select the community string that you have defined and click Remove . You cannot remove the default community string set. Agent Mode: Select the SNMP version that you want to use it. And then click...
  • Page 33 SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Click to remove unwanted context name. Remove User Profile Configure SNMP v3 user table.. User ID: set up the username. Authentication Password: set up the authentication password. Privacy Password: set up the private password.
  • Page 34: Q O S Configuration

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Group Name: set up the group name. Click to add context name. Click to remove unwanted context name. Remove Access Table Configure SNMP v3 access table. Context Prefix: set up the context name.
  • Page 35: Igmp Configuration

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw QoS Configuration interface 4.1.31 IGMP C ONFIGURATION The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet Protocol (IP) suite. IP manages multicast traffic by using switches, routers, and hosts that support IGMP. Enabling IGMP allows the ports to detect IGMP queries and report packets and manage IP multicast traffic through the switch.
  • Page 36: Security

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw A message sent by a host to the querist to indicate that the host wants to be or is a Report member of a given group indicated in the report message.
  • Page 37 SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw IEEE 802.1x Protocol: .enable or disable 802.1x protocol. Radius Server IP: set the Radius Server IP address. Server Port: set the UDP destination port for authentication requests to the specified Radius Server.
  • Page 38: Mac Address Table

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw TX Period: set the period the port wait for retransmit next EAPOL PDU during an authentication session. Supplicant Timeout: set the period of time the switch waits for a supplicant response to an EAP request.
  • Page 39: Access Control List

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw and delete filtering MAC address. MAC Filtering interface MAC Address: Enter the MAC address that you want to filter. VID: Type in the VID of the MAC address. Click If you want to delete the MAC address from filtering table, select the MAC address and click...
  • Page 40: Dhcp Filter

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Current List: Display the current list information. Access Control List interface 4.1.32.4 DHCP Filter By the function, DHCP discover and DHCP request packets will NOT be forwarded to the port that you selected.
  • Page 41: System Reboot

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw save the all configuration to the flash memory. Save Configuration interface 4.1.35 S YSTEM EBOOT Reboot the switch in software reset. Click to reboot the system. Reboot System Reboot interface...
  • Page 42: Command Line Interface Management

    CLI M BOUT ANAGEMENT ESW-5242GP / ESW-5162GP also supports CLI management. You can use console or telnet to management switch by CLI. CLI Management by RS-232 Serial Console (9600, 8, none, 1, none) Before Configuring by RS-232 serial console, use an RJ45 to DB9-F cable to connect the Switches’ RS-232 Console port to your PC’s COM port.
  • Page 43 SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw (3)Select to use COM port number (4) The COM port properties setting, 9600 for Bits per second, 8 for Data bits, None for Parity, 1 for Stop bits and none for...
  • Page 44: Commands Level

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw (5) The Console login screen will appear. Use the keyboard enter the Console Username and Password that is same as the Web Browser password), and then press “Enter”. 5.2 C OMMANDS...
  • Page 45: Commands Set List

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Enter the Use this mode to configure parameters configure To exit to privileged that apply to your switch as a whole. Global command while switch(config)# EXEC mode, enter exit configuration in privileged or end EXEC mode.
  • Page 46: Port Commands Set

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw dhcpserver gateway switch(config)#dhcpserver gateway Configure gateway for DHCP clients. [Gateway] 192.168.1.254 dhcpserver dnsip Configure DNS IP for DHCP clients. switch(config)# dhcpserver dnsip 192.168.1.1 [DNS IP] dhcpserver leasetime Configure lease time (in hour).
  • Page 47: Trunk Commands Set

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw and zero means no limit. Set interface output bandwidth. Rate Range is from 100 kbps to 102400 bandwidth out switch(config)#interface fastEthernet 2 kbps or to 256000 kbps for giga [Value] switch(config-if)#bandwidth out 100 ports, and zero means no limit.
  • Page 48: Spanning Tree Commands Set

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Vlanmode To set switch VLAN mode. switch(vlan)# vlanmode portbase [portbase| 802.1q | gvrp] switch(vlan)# vlanmode 802.1q switch(vlan)# vlanmode gvrp no vlan Disable VLAN. Ported based VLAN configuration vlan port-based Add new port based VALN.
  • Page 49: Qos Commands Set

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw spanning-tree Use the spanning-tree hello-time switch(config)#spanning-tree hello-time 3 hello-time [seconds] global configuration command to specify the interval between hello bridge protocol data units (BPDUs). spanning-tree Use the spanning-tree forward-time switch(config)# spanning-tree forward-time 20...
  • Page 50: Mac / Filter Table Commands Set

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw Igmp-query auto Set IGMP query to auto mode. switch(config)#Igmp-query auto Igmp-query force Set IGMP query to force mode. switch(config)#Igmp-query force show igmp Displays the details of an IGMP switch#show igmp configuration configuration configuration.
  • Page 51: Port Mirroring Commands Set

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw group [Group Name ] security-level [NoAuthNoPriv|Auth NoPriv|AuthPriv] match-rule [Exact|Prifix] views [Read View Name] [Write View Name] [Notify View Name] snmpv3 mibview Configure the mibview table of switch(config)#snmpv3 mibview view V1 type view SNMPV3 agent.
  • Page 52: Tftp Commands Et

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw serverport global configuration command to [port ID] change the radious server port. 8021x system Use the 802.1x system account port switch(config)# 8021x system accountport accountport global configuration command to 1816 [port ID] change the accounting port.
  • Page 53: Sntp Commands Et

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw show systemlog Show system log client & server switch#show systemlog information. no systemlog Disable systemlog function. switch(config)#no systemlog smtp enable Enable SMTP function. switch(config)#smtp enable smtp serverip Configure SMTP server IP.
  • Page 54: Ccess Ontrol Ist Ommands Et

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw no sntp daylight Disable daylight saving time. switch(config)#no sntp daylight 5.3.15 CCESS ONTROL OMMANDS Commands Level Description Example show acl Show the information of access switch#show acl control list table. acl gid...
  • Page 55: Technical Specifications

    SUNIX Co., Ltd. TEL : +886-2-8913-1987 Email : info@sunix-ncci.com.tw 6. Technical Specifications Technology IEEE802.3 10BASE-T IEEE802.3u 100BASE-TX IEEE802.3z Gigabit Fiber IEE802.3ab 1000Base-T IEEE802.3x Flow Control and Back pressure Ethernet Standards IEEE802.3ad Port trunk with LACP IEEE802.1d Spanning tree protocol IEEE802.1w Rapid Spanning tree protocol IEEE802.1p Class of service...