Safety Information - ADS 5240 Operation Manual

240w ac/dc mixer amplifier
Table of Contents

Advertisement

Safety Information

WARNING – THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with the following code
Green and yellow Earth (E); Blue: Neutral (N); Brown: Live (L).
As the colours of the wires in the mains lead of the apparatus may not correspond with the
coloured markings identifying the terminals in your plug proceed as follows
the wire coloured green and yellow must be connected to the terminal
marked by the letter E (or the safety earth symbol), or coloured green and
yellow
the wire coloured blue must be connected to the terminal marked with the
letter N or coloured black
the wire coloured brown must be connected to the terminal marked with the
letter L or coloured red.
If a 13-amp (BS1363) plug or other type of plug is used, a 5-amp fuse must be fitted either
in the plug or at the distribution board.
IEC Mains Inlet Socket
For mains connection other than in the UK, refer to your local requirements for connection
to the mains supply.
Green/Yellow Earth
Blue Neutral
Fuse Holder
Page 6 of 16
13A Mains Plug Wiring (UK)
Brown Live
Fuse (max 5A)

Advertisement

Table of Contents
loading