E. Combustible Mantel
See Figure 11.4.
A combustible mantel may be positioned no lower
than 12 in. (305 mm) above the top of the fi replace
opening.
A combustible mantel may have a maximum depth of
12 in. (305 mm).
Combustible trim and materials cannot be placed within
6 in. (152 mm) of the fi replace opening (top or sides).
Combustible materials projecting more than 1-1/2 in.
(38 mm) shall not be placed within 12 in. (305 mm) from
the top of the fi replace opening.
Combustible trim must not cover the metal surfaces of
the fi replace.
Mantel clearance is in accordance with Section 7-3.3.3
of ANSI/NFPA211.
F. Sidewalls/Surrounds
Adjacent combustible sidewalls must be located
a minimum of 12 in. (305 mm) from the fireplace
opening.
Combustible or non-combustible mantel legs, surrounds
and stub walls may be constructed per Figure 11.5.
11 3/8 in.
[289 mm]
Figure 11.5 Mantel Leg or Wall Projections (acceptable on both sides of opening)
40
Gridlines at 1 in. scale
FLUSH
FRONT
fireplace opening
width of fireplace
12 in.
[305 mm]
Heat & Glo • HST-48D US-CAN • 4012-040 • Rev F • 11/08
Figure 11.4 Clearances to Mantels or other Combustibles above
Fireplace
42 in.
[1067 mm]
47 in.
[1194 mm]
12 in.
(305 mm)
max.
12 in.
(305 mm)
Gas
min.
Knockout
4 in.
BRICK
[102 mm]
FRONT
12 in.
[305 mm]
9 3/4 in.
[248 mm]