Features
ELECTRONIC CONTROL
INSTRUCTIONS
MODE select button
1
Selects the appropriate operating mode. Each time you press the but-
ton, a mode is selected in a sequence that goes from AUTO, COOL,
DRY, FAN and HEAT(cooling models only without HEAT feature). The
mode indicator light illuminates in the corresponding mode setting.
TIMER button
2
Used to initiate the AUTO ON start time and AUTO OFF stop time pro-
gram, in conjuction with the up arrow & down arrow buttons.
POWER button
3
Turns power on/off.
SLEEP button
4
Used to initiate the SLEEP operation.
FAN button
5
Controls the fan speed. Press to toggle between two fan speeds: LOW
and HIGH. The fan speed indicator light indicates different fan set-
tings.
6
UP and DOWN buttons
Used to adjust (increase /decrease) temperature settings (1°C/2°F
increments) in a range of 17°C(62°F) to 30°C(88°F) or the TIMER set-
ting in a range of 0~24hrs. The control is capable of displaying
temperature in degrees Fahrenheit or degrees Celsius. To convert
from one to the other, press and hold the Up and Down buttons at the
same time for 3 seconds.
LED Display
7
Shows the set temperature in °C or °F and the Auto-timer settings.
While on DRY and FAN modes, it shows the room temperature.
Also displays the following error codes:
E1 - Room temperature sensor error-Unplug the unit and plug
it back in. If error repeats, call for service.
E2 - Evaporator temperature sensor error- Unplug the unit and
plug it back in. If error repeats, call for service.
E4 - Display panel communication error - Unplug the unit and
plug it back in. If error repeats call for service.
P1 - Bottom tray is full - Connect the drain hose and drain the
collected water away. If error repeats, call for service.
ION button(optional)
8
By pressing the ION button, the ion generator is energized and will
help to remove pollen and impurities from the air, and trap them in the
filter. Press it again to stop the function.
7